a Pull the new star pleated filter over the
filter vibrator on the spacer such that
the vibrating elements are aligned
centrally in the filter bags.
b Place the spacer with star pleated fil-
ter and filter vibrator on the filter ring.
c Lock the spacer.
8. Fit and lock the suction head.
Troubleshooting guide
DANGER
Unintentional start-up of the device /
electric shock
Unintentional start-up of the suction motor
can cause injuries. Voltage present on
electrical parts can cause an electric shock.
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Have all checks and work on electrical
parts performed by an qualified technician.
Note
The device must be switched off immedi-
ately in the event of a malfunction. The mal-
function must be eliminated before
switching the device on again.
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
Suction turbine does not start up
1. Check the socket and the power supply
fuse.
2. Check the mains cable and the mains
plug of the device.
3. Switch the device on.
Suction power decreases
1. Remove the blockages from the suction
nozzle, the suction pipe or the suction
hose.
2. Clean the filter (see chapter Cleaning
the filter).
3. Empty the dirt receptacle (see chapter
Emptying the dirt receptacle).
Escaping dust when vacuuming
1. Check the seating of the filter and cor-
rect if necessary.
2. Clean the filter (see chapter Cleaning
the filter).
16
3. Replace the filter (see chapter Chang-
ing/replacing the filter).
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Technical data
Electrical connection
Mains voltage
Phase
Power frequency
Power
Protection class
Protection class
Maximum permissible
mains grid impedance
Dimensions and weights
Typical operating weight
Length x width x height
Filter area
Ambient conditions
Storage temperature
Device performance data
Container capacity
Vacuum (with pressure re-
lief valve)
Air quantity
Suction hose connection
Nominal width of the suc-
tion hose
Filter order number
English
Warranty
V
~
Hz
W
Ω
kg
mm
2
m
°C
l
kPa
l/s
220-
240
1
50-60
3150
IPX4
I*
0.195+
j0.122
76
1020 x
680 x
1720
2.24
-10-40
100
25.4
3 x 74
NW
DN70
DN40/
50/70
6.907-
611.0