Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 35)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance (see page 44)
Dimensions (see page 36)
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
4
English
+
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 60°C
70°C / 4 min
Cause
- EcoSmart® dirty or leaking
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Crossflow
Assembly (see page 33)
Flow diagram (see page 37)
free flow
Spare parts (see page 38)
XXX = Colors
000 = Chrome Plated
090 = Chrome Plated/Gold Plated
140 = Brushed Bronze
250 = Brushed Gold-Optic
340 = Brushed Black Chrome
400 = White/Chrome Plated
670 = Matt Black
700 = Matt White
990 = Polished Gold-Optic
Special accessories (see page 38)
order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep
enough)
Cleaning (see page 47)
Operation (see page 46)
Test certificate (see page 48)
Remedy
- Clean or exchange EcoSmart®
(see page 44)
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange cartridge