1. Remove the (4) corner screws attaching the flow meter electronics and
Bluetooth module to the meter and lift away from the meter.
2. Remove the AAA batteries from the display and then the CR2477 3V lithium
cell battery from the Bluetooth module.
3. Check the battery terminals and remove any corrosion.
4. Install the new batteries, preferably starting with the AAA cell battery. For the
AAA batteries, make sure the positive posts are positioned correctly. When
the batteries are installed correctly, the flow meter powers on automatically
and the display will show information.
5. Install the CR2477 battery with the positive side up.
6. Make sure the seal is fully seated before placing the flow meter electronics
back on the turbine. Make sure wires aren't obstructing the seal. Tighten the
(4) screws previously removed.
7. Do not clean exterior of flow meter assembly with Isopropyl Alcohol, use a
damp cloth as needed.
NOTE: It is recommended to replace the batteries every year.