When wiring terminal blocks, please ensure that the poles/terminals are correctly assigned (see figure under the connection examples for terminal
blocks). The manufacturer takes no responsibility for damage caused by faulty wiring! Further information on the correct wiring of terminal block
connections ("terminal blocks") can be found in the section TERMINAL BLOCK CONNECTIONS in these instructions.
TERMINAL BLOCK CONNECTIONS
AUX OUT OUTPUT LINE
balanced wiring
1
2
3
3
XLR f
2
1
10
2
+
-/G
XLR m
+
unbalanced wiring
+
-/G
-/G
1