Addressing via DMX/RDM

RDM (Remote Device Management) is an open and bi-directional protocol standard for DMX-controlled devices. The
permanently transmitted DMX data flow briefly pauses (several milliseconds), and an RDM data package (message) is
sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an answer (semi-
duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents several subscribers from
answering simultaneously.
The protocol makes it possible to receive status information about a unit or to change configurations on a unit. Chang-
ing the configuration means, e.g. changing the DMX address. The prerequisite for this function is a RDM-compatible
controller. Read the corresponding operating instructions
RDM parameters
General parameters
COMMS_STATUS
STATUS_MESSAGES
STATUS_ID_DESCRIPTION
SUPPORTED_PARAMETERS
PARAMETER_DESCRIPTION
DEVICE_INFO
PRODUCT_DETAIL_ID_LIST
DEVICE_MODEL_DESCRIPTION
MANUFACTURER_LABEL
DEVICE_LABEL
SOFTWARE_VERSION_LABEL
DMX_START_ADDRESS
SENSOR_DEFINITION
SENSOR_VALUE
DEVICE_HOURS
DEVICE_POWER_CYCLES
IDENTIFY_DEVICE
RESET_DEVICE
Specific parameters
KENNLINIENPUNKT_X1
KENNLINIENPUNKT_Y1
KENNLINIENPUNKT_X2
KENNLINIENPUNKT_Y2
KENNLINIENPUNKT_X3
KENNLINIENPUNKT_Y3
RUNTIME_HOURS
STARTUP_COUNTER
CONFIG_MODE
STS_OVERTEMP
STS_OVERVOLTAGE_PHASE
STS_UNDERVOLTAGE_PHASE
STS_OVERCURRENT
STS_BLOCKIERT
22
GET
SET
Description
CMD
CMD
Shows general status information of the bus interface
Used to manage status messages
Used to manage status messages
Overview of all RDM parameters
Description of all parameters
Brief overview of the most important features
Additional feature
Type designation
Manufacturer's designation
Labelling field
Firmware version number
Reading and setting the DMX start address
Sensor information
Sensor value
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Sensor 9
Sensor 10
Operating hour counter
Switch-on counter
0 = normal mode
1 = pump will switch on and off again at short intervals. This function is helpful for
identifying the device in the field.
Executes a reset.
1 = warm start
255 = cold start
GET
SET
Description
CMD
CMD
Support value 1 of the stored pump characteristic curve
Support value 2 of the stored pump characteristic curve
Support value 3 of the stored pump characteristic curve
Operating hour counter for the running period
Startup counter
Only for service purposes
Status message, overtemperature
Status message, overvoltage
Status message, undervoltage
Status message, operating voltage too high
Status message, motor blocked
TempLpErrorCount
Temperature error counter, PCB
TempWindErrorCount
Temperature error counter, motor
MotorFailureCount
Motor failure counter
ActualSpeed
Current actual speed
NominalSpeed
Current set point speed
PWM
Current PWM value
Temp
Operating temperature, electronic board
Winding Temp
Operating temperature, motor
Power Voltage
Current intermediate circuit voltage
Current Consumption
Current intermediate circuit current