Technical Data

Code
Description
Voltage
Current
Speed
Collar clamps
Base diameter
Maximum cutting depth:
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING
Before gaining access to the terminals all power sources should be disconnected.

Power requirements

WARNING
Tools with double insulation and reinforced insulation are built with a
polarized plug (one prong is wider than the other) This plug fits in any polarized outlet
and can only be connected one way. If the plug does not fit completely into the outlet,
reverse the plug. If it is not fitting, call a qualified electrician or install a polarized outlet.
Do not alter the plug in any way. Double insulation eliminates the need of a three-prong
grounded power plug or a grounded electric system.
When using an extension cable, make it has sufficient gauge to
WARNING
carry the current your tool will draw. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
the motor will overheat. The following table shows the right size to use depending on cable's length and the ampere
capability shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When using power tools outdoors use
Use". These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
127 V
5.6 A
3 1/2"
18 AWG x 2C with insulation temperature of 221 °F
Class II
La clase de construcción de la herramienta es: Aislamiento reforzado.
La clase de aislamiento térmico de los devanados del motor: Clase E
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
ROU-MN
102315
Compact Router
Frequency
Power
10 000 RPM - 30 000 RPM
For drills with 1/4" shanks
Maximum drill diameter
1
3
/
"
8
IP Grade
El cable de alimentación tiene sujeta-cables tipo: Y
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "Outdoors
60 Hz
0.95 HP
1 1/8"
IP 20
Authorized Service Center.
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3