Model
Power cable
Connecting cable
Voltage transformer
Model
Power cable
Connecting cable
At 220 V 7 K, 9 K, 12 K, 15 K, 16 K, 18 K, 22 K, 24 K, 30 K, the backup value for the air conditioning interior unit is: 50 T, 3.15 A
At 110 V 7 K, 9 K, 12 K, the backup value for the air conditioning interior unit is: 50 T, 3.15 A
125 V 7 K, 9 K, 12 K the backup value for the air conditioning exterior unit is: 61 T, 15 A
250 V 18 K, 22 K, 24 K the backup value for the air conditioning exterior unit is: 65 T, 25 A!

Circuit Diagram

The circuit diagram may vary for different models. Please observe the
circuit diagrams on the interior and exterior units.
For the interior unit, you will find the circuit diagram (7) under the front
panel (1).
For the exterior unit, you will find the circuit diagram stuck to the reverse
side of the connector cover (15).
NOTE:
For some models, the cables have been connected by the manufac-
turer to the main circuit board of the interior unit without terminal strips.
Operation
Tableside Control
If the remote control is not functioning or maintenance is required, pro-
ceed as follows:
CL6045QCCB_IM

Cable Specifications

Installation Instructions – Information for the Installer
Cooling agent (Btu / h)
N
L
E
N
L
1
2
3
Installation Instructions – Installation Information
Cooling agent (Btu / h)
1.0 mm² (1.5 mm²)
N
AWG18 (AWG16)
1.0 mm² (1.5 mm²)
L
AWG18 (AWG16)
1.0 mm² (1.5 mm²)
E
AWG18 (AWG16)
N
1.0 mm² (1.5 mm²)
L
1.0 mm² (1.5 mm²)
1
1.0 mm² (1.5 mm²)
9k
12k
1.0 mm²
1.0 mm² (1.5 mm²)
AWG18
AWG18 (AWG16)
1.0 mm²
1.0 mm² (1.5 mm²)
AWG18
AWG18 (AWG16)
1.0 mm²
1.0 mm² (1.5 mm²)
AWG18
AWG18 (AWG16)
1.0 mm²
1.0 mm² (1.5 mm²)
1.0 mm²
1.0 mm² (1.5 mm²)
1.0 mm²
1.0 mm² (1.5 mm²)
0.75 mm²
0.75 mm²
0.75 mm²
0.75 mm²
9k
12k
Cross section
1.0 mm² (1.5 mm²)
AWG18 (AWG16)
1.0 mm² (1.5 mm²)
AWG18 (AWG16)
1.0 mm² (1.5 mm²)
AWG18 (AWG16)
1.0 mm² (1.5 mm²)
1.0 mm² (1.5 mm²)
1.0 mm² (1.5 mm²)
1. Open the front cover and lift it upwards until you reach the
2. Pressing the
button will cause the cooling function to start. (You will
hear a beep)
3. Pressing the
button within 3 seconds will cause the heating func-
tion to start. (You will hear two beeps.)
4. To switch it off, press the
button again. (You will hear a long beep.)
NOTE:
The external static pressure for the water pump on all models is 0 Pa.
Remote Control
1. Open the battery compartment cover on the rear side of the remote
control by pushing it in the direction of the arrow.
15 / 18k
1.5 mm²
AWG16
1.5 mm²
AWG16
1.5 mm²
AWG16
1.5 mm²
1.5 mm²
1.5 mm²
0.75 mm²
0.75 mm²
18 / 22k
1.5 mm²
AWG16
1.5 mm²
AWG16
1.5 mm²
AWG16
1.5 mm²
1.5 mm²
1.5 mm²
button.