DETAILED PERFORMANCE DATA FOR THE TML 500 LIFTING MAGNET
Values shown for load capacity are based on material S235 JR comparable to AISI 1020 Cold Rolled Steel
with the maximum, vertical breakaway force at 0° deviation from the load axis and additionally under a
6° inclined load in accordance with EN13155, in each case with a 3:1 safety factor. This manual does not
contain any instructions for use on round material, as the TML 500 is designed for flat material and round
material or arched objects may not be lifted.
Table 2
Thickness
of material
mm
2
3
4
5
6
8
10
15
>20
Thickness
of material
inch
0,08
0,12
0,16
0,20
0,25
0,30
0,40
0,50
>1
The maximum dimensions of the loads to be lifted depend to a large extent on the geometry and flexural
stiffness of the work pieces. If the material bends, an air gap will form under the magnetic surface which
will decrease the load-bearing capacity significantly. During each lift, watch for any deformation of the work
piece that might occur and, if necessary, check for any air gap developing at the edges of the TiN-coated
magnetic surface (e.g. with a sheet of paper; 80g/m2). Spreader bars with additional magnets may be
required to safely lift large or flexible loads.
Load capacity in kg
Clean, flat,
ground surface
Air gap <0.1 mm
50
44
130
110
195
170
300
260
360
315
455
395
490
430
500
440
500
440
Load capacity in lbs
Clean, flat,
ground surface
Air gap < 0.004 inches
110
90
285
245
430
370
660
575
800
575
1000
870
1090
940
1100
950
1100
970
Immediately stop the lift if there is any excessive
!
deformation or an air gap.
Never exceed the dimensions and/or the load-bearing
!
capacity of the material thickness given in the table 2.
Rusty,
slightly scratched surface
Air gap = 0.25 mm
45
39
115
100
160
140
240
205
270
235
310
270
360
310
365
315
370
320
Rusty,
slightly scratched surface
Air gap = 0.01 inches
100
85
255
220
355
305
525
455
595
510
685
590
785
680
800
690
815
705
Irregular,
rusty or rough surface
Air gap = 0.5 mm
40
35
85
72
135
115
190
165
220
190
240
205
250
215
250
220
260
225
Irregular,
rusty or rough surface
Air gap = 0.02 inches
90
75
185
160
295
255
415
360
480
415
525
455
540
470
545
475
555
480
21