INSTALLATION & USE
22'
RESCUE LADDER
FIGURE 1
22'
RESCUE LADDER
22'
RESCUE LADDER
FIGURE 2
FIGURE 3
FIGURE 5
FIGURE 6
22'
RESCUE LADDER
FIGURE 7
FIGURE 8
INSTALLATION & USE
1. The SafeWaze Rescue Ladder should be stored in a prominent location that is quickly accessible and
in close proximity to individuals working at heights. All employees must be trained in the location, and
proper use of, the Rescue Ladder (See Figure 1 and Figure 2).
2. After a fall event, the employee attempting the rescue must first ensure that the fall victim is conscious
and not injured to an extent that would inhibit their ability to use the Rescue Ladder. If the victim is
conscious and uninjured, the rescuer will obtain the rescue ladder from it's predetermined location
(See Figure 3).
WARNING: The individual performing rescue
operations must ensure they follow all fall
protection guidelines as rescue is peformed.
3. After obtaining the Rescue Ladder, the rescuer will attach the ladder to a suitable anchorage point.
The fallen victim's own anchor point can be used, or if impractical to do so, connected to a separate
anchor point. Ensure that the separate anchor point is in close enough proximity to the fall victim to
conduct the rescue. Connect to the suitable anchorage point by opening the top of the Rescue Ladder
Bag, and attach the top of the ladder assembly to the anchor point via the supplied carabiner
(See Figure 4).
WARNING: The anchor and structure must be
22'
RESCUE LADDER
able to support 5,000 lbf or (22kN). Only use an
approved ANSI Z359.18 Anchorage
A
FALL-ARREST
4. Once the Rescue Ladder is secured to the anchor point, the rescuer will drop the bag to deploy the
Rescue Ladder. The rescuer must avoid hitting the fall victim when dropping the Rescue Ladder
(See Figure 5, 6, 7).
5. Once the Rescue Ladder is deployed, the fall victim can begin climbing the Rescue Ladder to safety
(See Figure 8).
WARNING: Do not remove or disconnect any
fall protection equipment.
6. If the Rescue Ladder with Belay is being used (012-6042), deployment of the ladder is performed
in the same manner as the 020-6041 (See Figure 9, 10,11). Prior to the fall victim beginning to climb
however, the belay rope will be attached to the harness D-ring via the supplied carabiner. DO NOT
REMOVE ORIGINAL FALL PROTECTION EQUIPMENT! The user will then begin climbing to safety,
while the rescuer removes excess slack from the belay rope by pulling rope through the rope grab. DO
NOT ATTEMPT TO HOIST THE FALL VICTIM, BUT ALWAYS MAINTAIN CONSTANT TENSION ON
FIGURE 4
THE ROPE AS WORKER CLIMBS THE RESCUE LADDER (See Figure 12). The rope grab is NOT to be
used as a controlled descent device.
FIGURE 9
A
FALL-ARREST
22'
RESCUE LADDER
22'
RESCUE LADDER
FIGURE 11
I
I
225 Wilshire Ave, Concord NC, 28025
Phone: 704-262-7893
• Users should consult with their doctor to verify ability to safely absorb the forces of a fall arrest event.
Fitness level, age, and other health conditions can greatly affect an individuals ability to withstand fall
arrest forces. Women who are pregnant, individuals considered minors must not use any Safewaze
equipment.
• Never alter any part or add/remove components. Safewaze shall not be held responsible for injury or
death due to tampering.
• Equipment that is exposed to fall arrest forces MUST be IMMEDIATELY removed from service and
destroyed.
• Failure to follow these instructions and warnings could result in serious injury or death in the event
of a fall.
• A preplanned rescue procedure in the event of a fall is required. The rescue plan must be specific to
the project. The rescue plan must allow for employees to rescue themselves, or to be promptly rescued
by alternative means.
• Harnesses or connectors selected for use with any Safewaze Rescue Ladder must be compatible in
size and configuration. User must ensure compatibility of snap hooks, carabiners and other connectors.
Any connection which could allow disengagement must be eliminated. Snap hooks and carabiners must
be self locking and self closing and must never be hooked to each other.
• A Competent Person must conduct an analysis of the workplace and anticipate where workers will be
conducting their duties, the route they will take to reach their work, and the existing and potential fall
hazards they may be exposed to. The Competent Person must choose the fall protection equipment
to be utilized.
• Do not misuse equipment.
• Equipment designated for fall protection must never be used to lift, hang, support or hoist tools or
equipment unless specifically certified for such use.
INSPECTION
• Safewaze Rescue Ladders shall be inspected by the user prior to each use and at least annually by a
Competent Person. Annual Inspections must be documented. Severity of conditions during use may
neccesitate increased frequency of documented inspections.
• Rescue Ladders that fail inspection MUST be removed from service.
• Prior to each use, inspect the Rescue Ladder for deficiencies or damage, including, but not limited to,
sharp edges, rough edges, deformations, corrosion, pits, burrs, chemical exposure, extreme heat
Climber
Lift
exposure, or missing or illegible labels. If any deficiencies or defects are found, the Rescue Ladder must
IMMEDIATELY be removed from service.
WARRANTY
Safewaze warrants its products are free from defects in materials and construction under normal use
and service. Liability is not accepted for abuse, modification, improper use, destructive activity and
contaminated exposure.
MAINTENANCE & STORAGE
The Rescue Ladder can be cleaned with water and mild soap if necessary. User should remove all dirt,
possible corrosives, and contaminants from the anchor prior to, and after each use. Never use any type
of corrosive substance to clean the anchor.
Excess water should be blown out with compressed air. Hardware can be wiped off with a clean, dry
cloth.
FIGURE 10
When not in use, store the Rescue Ladder in a cool dry area where it will not be exposed to extreme
light, extreme heat, excessive moisture, or possibly corrosive chemicals or materials.
LABELS
A
FALL-ARREST
Date
22'
RESCUE LADDER
FIGURE 12
I
I
Fax: 704-262-9051
Email: info@safewaze.com
WARNING
020-6041: 22' Rescue Ladder
020-6042: 22' Rescue Ladder w/ Belay
Date of Manufacture: XX/XXXX