Descargar Imprimir esta página

Omni cubed SINK HOLE SAVER SHS-4A-20 Manual Del Usuario página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

Pump Recharging
1.
Plug the smart charger into a wall
outlet. Use only the included smart
charger.
2.
Connect the smart charger to the
pump.
3.
Observe the LED on the smart
charger. Red indicates charging; green
indicates fully charged. Recharging
requires up to 3 hours.
Vacuum Cup Testing
Follow these steps to determine if
maintenance or replacement parts are
needed.
1.
Place a cover on the cup.
2.
Connect the tubing in a closed loop.
3.
Pump the plunger until the red collar
remains hidden.
4.
Begin timing: The red collar should not
appear for at least 10 minutes.
9
en
omnicubed.com

Publicidad

loading