Troubleshooting
Types of
Indication
problems
Charger
No indicator
does not
lights on.
work.
Charger has
LED fault
no DC
indicator is ON.
output.
No charging
LED fault
current.
indicator is ON
and charging
percentage LED
bar flashing or
blinking in
sequence.
No charging
LED fault
current.
indicator is fast
flashing.
Full / float
LED fault
light will not
indicator is
come on
flashing. The
or full LED
charging
flashing.
percentage LED
bar is flashing or
ON.
Maintenance
The charger is maintenance free. If the power cord is damaged, the charger must not be
used. The case should be cleaned occasionally. The charger should be disconnected from
the power while cleaning.
Possible
Suggested solution
causes
No mains
Check mains connections and
power.
make sure power is switched ON.
Output is short
Check DC connection between
circuited.
charger and battery and make
sure they are not short circuiting.
Reverse
polarity
Check that the crocodile clips
connection to
have not fallen off the battery.
battery.
Check that the crocodile clips /
eyelets are connected to the
correct polarity.
Battery is
Check the battery condition, age
severely
etc.
sulphated.
Battery may need replacement.
Battery has a
damaged cell.
Check the battery capacity.
Overheat
Move battery and charger to
protection
cooler environment.
mode.
Check the battery charger.
Battery
Check the charger specification
capacity too
matches the battery capacity.
large for the
battery charge
Battery cannot be charged and
setting and it
must be replaced.
has timed out
or battery is
Charge rate selected might be too
slightly
low. Switch charger off and on
sulphated.
and try a higher charge rate
setting, providing it doesn't
exceed the maximum charge limit
for your battery.
8