North America:
DN15 - Valve internal threads NPT 1/2"
DN20 - Valve internal threads NPT 3/4"
DN25 - Valve internal threads NPT 1"
DN32 -Valve internal threads NPT 1-1/4"
PRODUCT WARRANTY AND
REGULATORY STATEMENTS
Standards and Body Approval
Actuator
• CE EMC 2014/30/EU
• CE RED 2014/53/EU
• EN 60730-1
• EN 60730-2-14
• UKCA
• CAN/CSA C22.2
• UL 60730-1
• UL 60730-2-14
Power Adapter
• CE EMC 2014/30/EU
• CE LVD 2014/35/EU
• UKCA
Valve
• Europe
—
ACS (France)
—
WRAS (Reg. 4)
Environmental and Normative
Characteristics
• Insulation class actuator: III Extra low voltage
• Insulation class power adapter: II Double insulated
• Overvoltage category: category 2
• Pollution degree: 2
• Actuator as per EN/UL60730-1: Type 1 action
• Class A control
Valve Certification
• NSF / ANSI 61
• NSF / ANSI 372
Packaging
• EU 94/62/EC
• WEEE 2012/19/EU, ES 116
• RoHS 2011/65/EU,
ES 50040083
• REACH 1907/2006
• Proposition 65
• FCC part 15, subpart C
• RSS-247
• WiFi certified
• Bluetooth SIG
• UL listed / recognized
• FCC
• North America
—
NSF / ANSI 61
—
NSF / ANSI 372
L5 WIFI WATER LEAK SHUTOFF VALVE
FCC Regulations
§ 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions:
1 This device may not cause harmful interference, and
2 This device must accept any interference received,
including interference that may cause undesired operation.
IC REGULATIONS RSS-GEN
This device complies with Industry Canada's license-exempt
RSSs. Operation is subject to the following two conditions:
1 This device may not cause interference; and
2 This device must accept any interference, including
interference that may cause undesired operation of the
device.
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the
party responsible for compliance could void the user's
authority to operate the equipment.
RESIDEO-Extended Producer Responsibility
The product should not be disposed of with other household
waste. Check for the nearest authorized collection centers or
authorized recyclers. The correct disposal of end-of-life
equipment will help prevent potential negative consequences
for the environment and human health.
5-Year Limited Warranty
For warranty information, go to resideo.com
Disclaimer
• Product is not designed for continuous valve open/close
operation. Valve close/open cycle should be performed
max. once per 10 minutes to avoid product overheat.
• Product is designed for indoor use only.
• Valves, supplied as original accessory, are designed for
potable water (drinking water).
CAUTION
• When water is shut off by L5, it may cause damage to the
appliances and accessories that are connected to the
water main due to lack of water.
• Only for domestic water usage and to be installed indoors.
• Backflow preventers are required if used to control outside
water supply lines.
• Must be installed down stream of pressure tank.
• Must NOT be installed on system with external hot water
source.
• Must NOT install on fire sprinkler or suppression systems.
Installation on fire sprinkler or suppression systems may
cause it not to function in an emergency.
Full product manual is available at www.resideo.com
5
33-00607EFS—03