rePLAcINg THe UVc LAMP
C
D
D
C
• Pick up the plastic lamp head and pull in the direction from C to D by using the thumb
and index finger. Note: Do not touch the end of the UVC lamp with the other
internal components of the fixture. Install the new UVC lamps and tighten.
Immediately open the window if the UVC lamps is broken accidently. Deal with the
broken UVC lamps according to the local environmental protection agency.
LIgHT DISTrIIBUTION
• Graphical plots of luminaire's UV irradiance profile at GUD=200mm.
2.50E-05
2.00E-05
1.50E-05
1.00E-05
5.00E-06
0.00E+00
0
50
100
150
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
a) This equipment is designed for use with germicidal UV radiation sources and must be installed in compliance with competent technical directions to prevent risk of personal
injury from UV radiation.
b) UV radiation can pose a risk of personal injury. Overexposure can result in damage to eyes and bare skin. To reduce the risk of overexposure this equipment must be installed in
accordance with the manufacturer's site planning recommendations. This may include instructions on the relative location of each germicidal system component, the minimum
distances between UV generating devices and other objects or surfaces, and protection from line-of-sight exposure to UV radiation in occupied spaces located above the
equipment mounting area (e.g. upper floor balconies, open staircases, etc.)
c) UV and optical radiation can be reflected by surrounding surfaces such as ceilings and walls. Since the reflective properties of surfaces can vary widely, it should be considered
as part of site planning. Follow the manufacturer's recommendations for selecting appropriate ceiling and wall finishes.
d) IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT PERSONS WILL NOT BE EXPOSED TO EXCESSIVE UV OR OPTICAL RADIATION DURING EQUIPMENT OPERATION. THIS
WILL REQUIRE THE INSTALLER TO CONDUCT AN ASSESSMENT OF IRRANDIANCE OR ILLUMINANCE LEVELS IN THE SURROUNDING OCCUPIED SPACES PRIOR TO OCCUPANCY.
e) Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
f) Maintenance and servicing of this UV generating equipment shall be performed by authorized personnel. Service personnel must wear appropriate Personal Protective Equipment
(PPE) if the equipment will be in operation during the maintenance or servicing work. Contact the equipment manufacturer for PPE recommendations and guidance.
g) When replacing UV lamps, use only the model ZW30D15W-U210G-2G11, MANUFACTURED BY Foshan Youweishi optoelectronics Technology Co., Ltd.
h) The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
i) Do not use this equipment for other than intended use.
j) Manufacturer: ETI Solid State Lighting(Zhuhai)Ltd
WArNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock,
fire, or other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit
breaker. • Risk of Electric Shock • Suitable for indoor and dry locations. • Do not mount near flammable materials or electric heaters. • Do not let power supply cords touch a
hot surface. • The product should be installed and operated by a qualified electrician or technician in accordance with relevant local codes. • The final installation must be
approved by the appropriate qualified electrical/building inspector(s). Refer to safety instructions in manual for more information. Refer to www.bluehalolighting.com for more
test reports.
NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures: Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into
an outlet on a circuit different from that to which the receiver is connected, and consult the dealer or an experienced radio/TV technician for help.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
MAINTENANCE: See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
200
250
300
350
400
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-eTI-SSLI (1-855-384-7754) www.eTiSSL.com
• After replacing, install the safety rope and the front panel, then connect the
ground wire. Open the small cover and keep it at 90 degree to the fixture surface.
Install the front panel to the fixture and tighten, use the screw to lock the
small cover by screwdriver.
450