The course of the bar can be modified to rectify this problem by moving the vibration-damping plugs of the mechanical stop back
or forward), by means of the lock nuts of the plugs.
Note: the memorisation procedure on the control unit must be repeated each time the position of the mechanical stops
is modified (see K206M instructions).
Once the adjustment has been made, turn the power back on and perform the memorisation procedure on the control
unit (see K206M instructions), and check the correct position of the bar from the second automatic manoeuvre (the first
manoeuvre is for the control unit to acquire the new stops), if the position is incorrect repeat the procedure.
6.12 Last operations
When the correct operation of all devices controlling the bar has been checked, make sure everything is reset before handing
over to the users. Place signs warning people about the barrier where they can be easily read.
7. USE
The barrier has been exclusively designed to limit the flow of vehicles and/or persons in restricted entrances by means of a bar.
In the event of blackout, functioning can be guaranteed by means of an optional 12V dry battery having an autonomy of appro-
ximately 100 manoeuvres (LUXE-S).
Furthermore, it also comprises electrical equipment and therefore must be approached and used with caution and foresight. In
particular we recommend:
• not to touch the equipment with wet hands and/or bare or wet feet;
• not to perform the automatic or semiautomatic function in the presence of known or suspected malfunctions;
• not to pull the cable to disconnect the equipment;
• not to let children, or those unable, use the cabinet keys or controls (including remote controls) even if only to play with;
• not to operate the barrier until it is completely in view;
• not to enter within the operating range while it is moving, wait for it to stop;
• not to rest against the bar or cabinet for any reason, even when the barrier is inactive and do not remain within the operating
range of the barrier;
• not to let children or animal play within the operating range of the barrier;
• not to use the barrier for purposes (e.g. lifting of weights or persons) other than those foreseen. The manufacture holds no
responsibility what so ever for damages caused by the said actions;
• to perform periodic maintenance by specialised personnel;
• if there is a fault, turn off the power supply. Use the manual manoeuvre only if safe. Do not attempt to resolve the problem
yourself, contact a qualified technician of the manufacturer or authorised by the manufacturer. In any case, make sure that the
spare parts are original so that the safety of the barrier is not compromised.
8. MAINTENANCE
To be performed by specialised personnel only after having turned off the power supply.
After every 100,000 manoeuvres, check:
-
the greasing of the spring;
-
the balance of the bar (see chapter "Bar fixing, spring fitting and bar balancing");
-
the efficiency of the force;
-
the integrity of the battery, if present;
-
The efficiency of the protection and safety devices;
-
the wear on the mechanical stops and the adjustment of the limit switches (see chapter "Limit switch adjustment").
The above mentioned maintenance is vital in order that the product functions correctly throughout time.
In general
It must be impossible for third parties to operate the barrier during maintenance; therefore turn off the mains power supply (and
battery if present).
Release the bar first in order to facilitate the operation.
Greasing
1_ open the cabinet door;
2_ grease the eyelets of the screws of the balancing spring;
3_ grease the contact points between the cam of the manual release and the release lever;
4_ keep away from possible moving gears or mechanical parts.
FREQUENCY: every 100,000 manoeuvres or 6 months, failing which the guarantee lapses.
N.B it is highly recommended to use high resistance grease based on calcium soap.
Bar balancing
Check the bar is balanced correctly repeating the operations described in "Bar fixing, spring fitting and bar balancing". This opera-
tion is fundamental for the correct functioning and duration of the barrier. If necessary, increase the preloading of the springs
in order to compensate for its wear. See the subsequent paragraph "Extraordinary maintenance and repairs" in the event the
springs need to be changed.
FREQUENCY: every 100.000 manoeuvres or 6 months, failing which the guarantee lapses.
Control of the force limitation efficiency
Check the correspondence between the true operation and the operation established during installation.
FREQUENCY: every 100.000 manoeuvres or 6 months, failing which the guarantee lapses.
Control of the 12V dc battery
Check the charge level of the battery by means of a tester. If replacement is necessary, substitute the flat battery with an original
and do not dispose of it in the environment.
FREQUENCY: every 100.000 manoeuvres or 6 months, failing which the guarantee lapses.