Descargar Imprimir esta página

ABSINA 52-230-1005 Instrucciones De Uso página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ERROR
The charging cable has several monitoring functions that are indicated by the LEDs.
LED
LED
DESCRIPTION
LED RED
GREEN
BLUE
Standby
Normal connection
Charging
Charging
completed
Failed self-test
Low voltage
2x
3x
Over voltage
4x
Leakage current
5x
Over current
Charger
6x
overheated
7x
PE error
=
= ON
OFF
DECLARATION
Sleep mode.
Charging cable is connected to the vehicle.
Battery is charging.
Battery is fully charged.
The control box cannot establish communication with the vehicle. Check that the
connectors are correctly seated and check for dirt in the de-energised state. If the fault
cannot be rectified, send the charging cable to the manufacturer for inspection.
The supply voltage is outside the tolerance range. Check the mains voltage.
The supply voltage is outside the tolerance range. Check the mains voltage.
The control box detects a fault current. Stop charging, disconnect the charging cable
from the vehicle and check the wiring / vehicle. Visit a specialist workshop.
The charging current is above the maximum value. Stop charging and check the
compatibility of the charging cable.
The control box is overheated. This can be caused, for example, by direct sunlight during
the charging process. The charging process is interrupted. After cooling down, the
charging process starts automatically.
The control box detects a fault in the PE line. Check mains socket / mains connection.