8.1.1 List of equipment parameters
Parameter Description
A
Tank lower probe temperature
B
Tank upper probe temperature
C
Defrost probe temperature
D
Inlet air probe temperature
E
Evaporator input probe temperature
F
Evaporator outlet probe temperature
G
Compressor delivery temperature
H
Solar collector probe temperature (PT1000) 0÷150°C
I
EEV opening steps
J
Power board firmware version
L
User interface firmware version
Hysteresis on lower tank probe for heat
P1
pump operation
P2
Heating element switch-on delay
P3
Anti-legionella temperature set-point
P4
Anti-legionella duration
P5
Defrost mode
P6
Heating element use during defrosting
P7
Interval between defrost cycles
P8
Temperature for defrost start
P9
Temperature for defrost end
P10
Defrost cycle max. duration
P11
Tank probe temperature shown on display
P12
Type of external pump operation
Type of hot water recirculating pump
P13
operation
Type of evaporator fan (EC; AC; AC with dou-
P14
ble speed; EC with dynamic speed control)
Type of safety flow switch for hot / solar
P15
water, low pressure switch activation
P16
Solar thermal supplement
Heat pump start delay after release DIG.1 in
P17
solar mode = 1 (with DIG1)
Tank lower probe temperature for heat
P18
pump stop in solar mode = 1 (with DIG.1)
Hysteresis for pump switch-on in solar mode
P19
= 2 (solar thermal system control)
Solar shutter / discharge valve intervention
P20
temperature in solar mode = 2 (solar
thermal system control)
Tank lower probe temperature for heat
P21
pump stop in photovoltaic mode
Range
-30÷99°C
-30÷99°C
-30÷99°C
-30÷99°C
-30÷99°C
-30÷99°C
0÷125°C
30÷500
0÷99
0÷99
2÷15°C
0÷90 min
50°C÷75°C
0÷90 min
0 = compressor stop
1 = hot-gas
0 = off
1 = on
30÷90 min
-30÷0°C
2÷30°C
3min÷12min
0 = lower
1 = upper
0 = function excluded
1 = recirculation function
2 = solar function
0 = operation with HP
1 = continuous operation
0 = EC
1 = AC
2 = AC with double speed
3 = EC with dynamic speed
control
0 = NC
1 = NO
0 = NC
1 = NO
2 = low pressure selection
switch
10÷60min
20÷60°C
5÷20°C
100÷150°C
30÷70°C
cod. 3541T630 - Rev. 04 - 12/2021
Default
Measured value
Measured value
Measured value
Measured value
Measured value / "0°C" if P33 = 0
Measured value / "0°C" if P33 = 0
Measured value / "0°C" if P33 = 0
Measured value / "0°C" if P16 = 2
Measured value or value of P40 if
P39 = 1
Current value
Current value
7°C
6 min
75°C
30 min
0
0
45 min
-2°C
3°C
8 min
1
1
0
1
0
0
20 min
40°C
10°C
140°C
62°C
Notes
Not modifiable
Not modifiable
Not modifiable
Not modifiable
Not modifiable (1)
Not modifiable (1)
Not modifiable (1)
Not modifiable (1)
Not modifiable (1)
Not modifiable
Not modifiable
Modifiable
Function excluded
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable