Device elements (fig. I)
Overview
1 Union nut
2 Quick release connector for probe
3 Handle
4 Pressure cup
5 Trigger lever
6 Tank connector
7 Nozzle
8 8 bar safety valve
9 ¼" compressed air supply
10 Mark
11 Probe
12 Air valve
13 Hanging hook
14 Discharge control wheel
15 Product control wheel

Intended use

The device is suitable for spraying liquid bituminous
and waxy products. The device may only be used
in environments that are suitable for the type of prod-
ucts to be sprayed. The device is intended for use
with genuine Würth system accessories. Any other
use is considered improper.
The user is liable for any damage in the
event of improper use.
Technical data (fig. VI)
Item
Air consumption
Working pressure
Max. pressure:
Recommended max.
hose length
Min. inside diameter
of the hose
Air connection
Nozzle diameter
A pressure reducer with a filter [17], a pressure
meter [16] and a shut-off valve [18] for shutting off
the air supply are required in the compressed air
system.
0891 130 003
200 - 300 l/min
4/6 bar
8 bar
10 m
6 mm
Air quick release
coupling
Ø1.2 mm

Noise and Vibration Information

The equivalent continuous sound pressure level,
calculated on the A scale, is measured at a horizon-
tal distance of 50 cm. For bituminous products, this
level is <80 dB(A).
Operation (fig. III, IV, V)
Attention!
Dirty pipes could damage the device.
¾ Never tip the device through more than 45°.
¾ Do not close the device during use.
¾ After use, hang the device on the hanging
hook [13].
Connect the nailer to the compressed air supply.
Observe the technical data.
WARNING!
Danger due to pressure release
 The pressure cup [4] is under
pressure.
¾ Before the pressure cup [4] is
unscrewed, the safety valve [8]
must be turned clockwise to
release the contained pressure.
Installing the probes
Select the probe [11], which is most suitable
for the intended work, and connect it using the
quick-release connector [2].
Press the outer ring of the quick-release cou-
pling [2] back; the probe [11] is released
Product supply
Disconnect or interrupt the air supply and pull on
the ring of the safety valve [8], to let air out of
the tank [4].
Undo the tank by screwing in an anticlockwise
direction.
Fill product into the tank (maximum 1 litre)
Screw the tank in a clockwise direction until tight.