1. Opening the lock
1. Enter valid 6 digit combination (factory set to 1-2-3-4-5-6).
2. The lock will confirm a valid combination entry with a double signal.
3. Within 4 seconds, turn the handle to the open position.
4. Pull door open.
• Invalid Combination Entry - Lock will signal 3 times.
IMPORTANT NOTE: Change the combination before putting the lock into operation.
Wrong try penalty
• Entry of 4 consecutive invalid combinations starts a 5 minute delay period. - LED flashed
red at 10 second intervals.
• At the end of the delay period, 2 more consecutive invalid combinations will restart the
additional 5 minute delay period.
NOTE: Entry will not respond to keystrokes during delay period.
2. Changing your combination
CAUTION! Always perform this operation with the door open
1. Enter "0" six times.
2. Enter your existing 6 digit combination one time.
3. Enter your NEW 6 digit combination two times.
4. If a mistake is made wait 30 seconds and repeat steps 1 - 3.