Premier 70-W80-60
II. OPERATING INSTRUCTIONS
ELECTRICITY
Before connecting the product to electrical power, please verify that the specified electrical power supply
on the product description label corresponds with the local network electrical power supply.
The Product Description label with the specified electrical power supply can be found on the inside of the
cabinet, on the top left-hand side.
Installation of the product must only be undertaken by qualified and trained service personnel as per the
specifications listed in this manual.
The electrical safety of this cabinet can only be valid if it's earthed in accordance with current local laws and
regulations.
Earthing of the product is always required.
The manufacturer will not accept any responsibility for any damage arising from improper grounding.
Adhere to all electricity requirements stipulated by the local electrical regulations. The product's electricity
plug and wall socket must have the correct earth connectivity reading. If necessary employ a qualified
electrician.
GENERAL PRELIMINARY CHECKS
Make sure the cabinet is standing on level ground and is upright. If necessary, the adjustable feet of the
cabinet can be used to achieve this. All feet should be in contact with the ground. This is necessary for the
proper operation of the cabinet door.
Do not place the cabinet next to any heat-generating devices such as ovens, grills, and deep fryers. Do not
expose to direct sunlight. The heat that may be radiated by walls or floors must be insulated with appropriate
insulating material. The cabinet should be placed as far as possible from any heat source.
If the cabinet is re-located, allow three hours before re-starting. Plastic protection or tape should be removed
from the outer surfaces.
Ensure the cabinet is positioned so sufficient fresh air can flow to/from the cooling circuit and around the
surfaces of the cabinet. Leave at least 500 mm free space from the top of the cabinet.
If two refrigerators or freezers are to be placed side by side, there should be at least 50 mm space between
them.
Do not block any vent holes.
PRELIMINARY ELECTRICAL CHECKS
•
Check that the mains voltage and frequency of the socket conform to the information on
the product description label.
•
The cabinet is connected to the main outlet with a 13-16 Amp fuse as a serial connection.
•
Turn off the main fuse connected to the power cable.
•
Check that the plug on the cabinet is suitable for use with the available main socket and
that they fit together.
EN