Descargar Imprimir esta página

Cleaning And Maintenance; Troubleshooting - Dometic GP-PC-10-IP68 Instrucciones De Montaje Y De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33

Cleaning and maintenance

Load status LED (red)
9 Cleaning and maintenance
!
WARNING!
Unplug the device from the power supply before cleaning and maintenance
A
NOTICE! Damage hazard
• Never clean the device under running water or in dish water.
• Do not use sharp or hard objects, abrasive cleaning agents or bleach during clean-
ing as these can damage the device.
➤ Occasionally clean the device with a soft, damp cloth.
➤ Regularly check live cables or lines for insulation faults, breaks or loose connections.
The device is maintenance-free.

10 Troubleshooting

Error
Consumers are not
supplied with
energy.
10
Status
LED off: normal operation.
LED on: low/high voltage disconnect.
LED flashes: overload or short circuit of load.
Display
Cause
Battery is low.
Overcurrent/short circuit
of consumers /overtem-
perature protection.
Battery voltage > 15.5 / 31
V.
Battery cable or fuse is
damaged: battery shows
high internal resistance.
GP-PC-10-IP68
Remedy
Consumers will reconnect as soon
as battery is recharged.
Switch off all consumers. Remove
short circuit. The controller will
switch on consumers automatically
after maximum 1 minute.
Check if other sources are over-
charging the battery. If not, the
controller is damaged.
Check battery, fuse and wires.
EN

Publicidad

loading