Instructions how to
mount and adjust the
primary regulator
These regulators are exclusively
intended for use with CO2, N or
mixed gas (Nitrogen & CO2 Mix).
1. The gas cylinder should be
secured to prevent cylinder
from falling over.
2. Before connecting the regulator
briefly open the cylinder. This
will remove dust particles
from cylinder valve and ensure
cylinder has gas in it.
4
|
3. Verify inlet seal is present and
4. Using correct size wrench (1
5. Turn regulator shutoff to the
6. Turn cylinder valve knob
7. Turn the adjustment screw
8. Turn regulator shutoff valve
Fig 1B
in working condition.
1/18 in) tighten coupling nut
to HPC valve ensuring a leak
free seal. Do not overtighten!
off position (horizontal).
counterclockwise to open
cylinder and begin gas flow.
clockwise to desired output
pressure setting. Fig 1B
to open position (vertical)
allowing gas to flow to
system.
Fig 1C