Temperature control unit
1.
GENERAL INFORMATION
GLA810
The
Temperature control unit is an instrument for the management and control of Wood-burning Stoves and Fireplaces with Air heating.
1
2
Applied standards:
EN 60730-1 50081-1
EN 60730-1 A1 50081-2
Technical Specifications
Power supply: 230 VAC 50 Hz ± 10%
Absorption: 2 VA
Fan Output: 250 VAC 0.8A/
Fan Output: 250 VAC 1.5A Vers. boosted
Relay Output: 250 VAC 3A
Internal Fuse: T1.6 A
Reading probes: NTC10K @25°C; -10 ÷ 110 °C
NTC100K @25°C; -10 ÷ 300 °C
2.
INSTALLATION
Before carrying out any operation, m ake sure that the m ains voltage is sw itched off
• Install the product only in dry environments and in correct climatic conditions
• At the head of the installation, insert a bipolar switch in compliance with current regulations
• Avoid coupling the probe cables with power circuit cables
• Use electrical connection cables with conductors of appropriate section and in compliance
• Place the probes in such a way as to correctly detect the temperatures
• Make sure that the probe cables are not in direct/indirect contact with the flame
3.
ELECTRICAL CONNECTIONS
FU S E
T1 ,6 A
2 3 4
1
LINEA
230Vac
SCI
Initials
Terminals
LINE
IN SCI
S1
S2
VENT
SERV
6
GLA810 Glass
A
06055 Marsciano (PG) Italy Tel.+39.075.874.3905; Fax. +39.075.874.2239
Mechanical Characteristics
Material: ABS Plastic
Installation: Built in 3 Modules
Built in size: 120x80x55 mm
Degree of Protection: IP40
12 11 10 9
S2
S1
5 6 7
8
IN
VENT
SERV
230Vac
1 - 2
Mains Power Supply
3
4
Spark Consent
–
9
10
Air Temperature Probe
–
Room Temperature Probe /
11
12
–
Room Temp. Thermostat
5
6
Fan
–
7 - 8
Service Output
Safety Standards
Carefully read the following safety notes, so as to prevent any damage and
danger to people and things.
Before performing any work on the system, follow
•
the accident prevention rules,
the environmental protection rules,
•
•
the norms of the Istituto Nazionale per l'Assicurazione contro gli
Infortuni sul Lavoro (National Institute for Insurance against
Accidents at Work),
accepted safety rules.
•
•
These instructions for use are addressed exclusively to the
technical personnel.
Electrical work must be performed only by qualified electrical
•
engineering technicians.
The initial commissioning of the installation must be performed by
•
skilled personnel or by the manufacturer or by a technician
appointed by the same.
Conformity Declaration
TiEmme elettronica
info@tiemmeelettronica.it
All the control Outputs and probe Inputs are controlled
automatically according to the type/diagram of the chosen
Device
Characteristics
230 Vac 50 Hz ± 10%
Input 230 VAC 50 Hz ± 10%
Range of operation: -10°C
NTC 100K Measurement: -10
Range of operation: -10°C
NTC 10K Measurement: -10
230 VAC 0.8A
Free contacts: COM. (7) - N.O. (8)
Instruction
Conditions of Installation and
Operation
Operating temperature: 0 ÷ 40° C
Storage temperature: 0 ÷ 60 °C
Humidity: 85% @25°C
Installation.
Fig. 2 - Electric connections
÷
÷
Manual
180 °C
÷ 300
°C ± 1°C
125 °C
÷
110 °C ± 1°C