FAN MENU
6.2
Through this Menu you can select the Fan speed.
Pressing the keys K3 and K4 it is possible to see and modify on the Display the speed currently selected for the Fan
(LED
flashes).
MANUAL MODE: You can turn off the Fan by setting the speed P0, or by selecting a speed from P1 (minimum speed)
to P10 (maximum speed).
AUTOMATIC MODE: You cannot turn off the Fan, you can select a speed from P1 (minimum speed) to P10
(maximum speed).
PROPORTIONAL MODE: it is not possible to switch off the Fan nor to set a speed, it is only possible to see the speed
selected by the temperature control unit.
Press the K2 key to save the new value or wait 5 seconds.
Press the K1 key to exit without saving.
INSTALLER MENU
6.3
Access to this Menu is the RESPONSIBILITY of INSTALLATION TECHNICIANS or EXPERT PERSONNEL,
because the parameters shown, if modified, may render the product is not suitable for the application in use.
To access the MENU simultaneously press the keys K2 and K4 for about 3 seconds.
To scroll through the parameters, use the keys K3 and K4
To view the value of the parameter and enter for modification, press the key K2
To change the value, press the keys K3 and K4
To save the new value, press the key K2.
To exit without saving, press the key K1
Press the K1 key again to exit from the Menu or wait 60 seconds
Description
Fan Activation Air Thermostat
SAFETY Air Thermostat
ALARM Air Thermostat
FAN SAFETY Air Thermostat
Valve Opening Air Thermostat
Valve Closing Air Thermostat
SERVICE output Fan Activation Air Thermostat
Temperature Range for Proportional operation
Fan Activation hysteresis thermostat
SAFETY hysteresis thermostat
ALARM hysteresis thermostat
FAN SAFETY hysteresis thermostat
Opening Valve hysteresis thermostat
Closing Valve hysteresis thermostat
SERVICE output Activation hysteresis thermostat
Room temperature hysteresis thermostat
Fan Speed P01 (minimum)
Fan Speed P09 (ninth)
Fan Speed P10 (maximum)
Delay Time Damper Closing
Time of suspension of Acoustic alarm
Time of Fan Starting
Input Configuration S2; 0 = not used; 1 = Probe; 2 = Thermostat
SERVICE Output Configuration
Enabling FAN SAFETY
Enabling Air SAFETY
Enabling Air ALARM
Enabling Damper Start Function
Input Configuration S2; 1 = Probe; 2 = Thermostat
NOTES: Modifying UA01, UA09, UA10, the Fan immediately goes to the speed that you are calibrating in order to see the effect.
6.4 S1 INPUT CONFIGURATION ERROR
There may be two error conditions in the configuration of the product:
= 1
A.
P17
st input Thermostat
When the fire is off it will display the writing
When the stove is on it shows
P17 = 2
B.
nd input Probe NT100K.
By powering the control unit,
Lo
Hi
with the acoustic indicator in operation.
Err
will appear on the display.
Code
Min
Set
E01
30
50
E02
80
100
E03
100
130
E04
100
145
E05
20
30
E06
20
80
20
E07
50
E50
20
45
IE01
1
2
IE02
1
2
IE03
1
2
IE04
1
2
IE05
1
2
IE06
1
2
IE07
1
2
Ib01
0
1
UA01
0
30
0
UA09
70
UA10
0
100
t 06
0
10
t 07
1
5
t 08
0
0
P01
0
0
P02
0
0
P03
0
0
P04
0
1
P05
0
1
P12
0
0
1
P17
1
Max
U.O.M.
100
[°C]
140
[°C]
180
[°C]
180
[°C]
140
[°C]
140
[°C]
180
[°C]
100
[°C]
40
[°C]
40
[°C]
40
[°C]
40
[°C]
40
[°C]
40
[°C]
40
[°C]
20
[°C]
100
[%]
100
[%]
100
[%]
120
[min]
60
[min]
10
[sec]
2
n
3
n
1
n
1
n
1
n
1
n
2
n
9