Fan body assembly
1.
Place the metal tube of the fan motor (8) into the round hole in the
upper part of the housing (11). Make sure the tube is properly fitted
so that the fixing screw (10) can be screwed into the housing (11).
2.
Cover the metal part of the 4 wheels (13) with the 4 black plastic
covers and insert them into the four holes under the base (12).
3. Remove the floor support (14) from the thread at the bottom of the
housing (11). Place the fan with the two pins and the thread in the
upper part of the base (12) and insert it into the openings. Make sure
the housing is securely fixed to the pedestal.
Fan grille assembly
1.
Insert the motor shaft through the fan rear grille (7) and attach with
the rear grille nut (6).
2.
Place the blades on the motor shaft and fix them using the blade
nut (4).
3. Prepare the protective support (1) by screwing it into a circle with
the connecting screw and a screwdriver (turn 2-3 times only).
4. Place the front grille (3) exactly on the edge of the rear grille (7) and
connect them with the protective support. When it has encircled
the edges of the fan grilles, tighten the grille support screw with a
screwdriver.
5. Insert the mist hose (9) into the humidifier accessory (2) on the
front grille of the fan.
IMPORTANT: Do not operate the fan until the grilles and blades are
correctly installed.