It is configurable through a menu system accessible via a bus
LCD RAS or the ATS1482 Programming card.
The reader operates from 10 to 30 VDC.
ATS118x series readers are waterproof.
Mounting
The reader can be mounted on any flat surface by two pan
head screws, 3.0 to 3.5 mm diameter, located under the cover.
A slightly reduced range will be experienced when mounted on
metal surfaces.
It is not recommended to use countersunk screws.
If readers are placed closer than 10 cm from each other or if
the reader is installed on metal, the reader distance can be
shorter.
Do not install close to sources of powerful electromagnetic
disturbance.
Do not cut the cable shorter than 10 cm.
RAS addressing
The address of the reader for bus operations is set to the
default address RAS 16. You can change it using
a configuration card or accessing its online menu system when
connected to the RS-485 bus.
Note:
It is possible to change the reader address with
configuration card only when the reader is not polled.
Tamper
The reader is provided with a tamper facility (Figure 2, item T).
When connected to the bus, tamper data is transmitted to the
control panel with system data.
Reader programming
When using the reader with an Advisor Advanced control
panel, use the control panel programming menus. See Advisor
Advanced Installation and Programming Manual for details on
reader programming.
When using the reader with Advisor Master control panels, use
the reader built-in menus. Enter via the Installer menu and
select the menu "Remote Devices", then select "RAS".
The following options are available:
1.
Tamper Option: Enable/disable (default enabled).
2.
Reader Address: Changing reader address (1 to 16),
default = 16.
3.
RTE (egress): Enable/disable the request to exit and open
collector (default disabled).
4.
Backlight Option: Permanent/Access only (default Access
only).
5.
Buzzer Option: enable/disable reader buzzer (default
enabled).
6.
Card Bit Limit: The maximum length of the secure card
number in bits (the allowed range is 26 to 56 bits, default
is 48).
7.
Restore Factory Settings.
2 / 32
8.
Set Known Config Key: Reset the configuration key to the
predefined one 0102030405060708090A0B0C0D0E0F10.
Caution:
After the configuration is complete, change the
configuration key to prevent an unauthorized configuration
change.
9.
Secure Mode: Enable/disable (default enabled).
Reader wiring
Table 1: Reader wiring
Red
+12V
Positive 10 to 30 VDC supply, 80 mA
Black
0 Volts
DC supply ground
White
D+
RS-485 Data +
RS-485 Data −
Green
D−
Yellow
RTE
Request to exit button
Violet
OC
Open Collector output used to control a door
relay
Bare wire
Shield
Safety shield
Spare wires are not used.
Use WCAT54 cable to extend the standard shielded cable.
Make sure the shield is properly connected.
Cable length depends on the bus configuration.
Reader LEDs
Table 2: Reader LEDs
LED pos.
Colour
Left
Green
Red
Green / red flashing
Green flashing
Middle
Orange
Right
Red flashing
Specifications
Number of card combinations
Supply voltage
Supported card types
Connectivity
Cable
Normal operating current
Maximum operating current
Open collector output (OUT terminal) 14 VDC max. at 50 mA max.
LED
Wireless operating frequency
Maximum power output
Field strength
Material of design housing
P/N 466-2936-ML • REV G • ISS 17JAN23
Description
System disarmed
ATS125x: System armed
Valid card presented
Door open time
ATS4000: System not ready
ATS125x: Always on
Alarm
15
72x10
10 to 30 VDC
Secure mode: ATS145x series,
Mifare Desfire EV1
Unsecure mode: ACT4xxE,
Mifare Classic UID, Mifare
Desfire EV1 UID, Mifare Plus
UID, Mifare UltraLight UID
ATS data bus
LIYY 2 m
50 mA at 13.8 VDC
80 mA at 13.8 VDC
Tri-color
13.553 to 13.567 MHz
42 dBµA/m at 10 m
According to EN 300 330
Plastic