1. PARTS AND COMPONENTS

Fig. 4
1.
Tank
2.
Disinfection UV light
3.
7 nozzles
4.
Safety lock
5.
Tank cover
6.
360º rotary nozzle
7.
Handle knob
8.
Nozzle release button
9.
Pause button
10. UV/ON/OFF knob
11.
Pressure control knob with 10 pressure settings
Fig. 5
A.
High pressure regular nozzle x3
B.
Periodontal nozzle x1
C.
Braces nozzle x1
D.
Dental plaque nozzle x1
E.
Tongue cleaner nozzle x1

2. BEFORE USE

-
Take the device out of its package and remove all packaging material.
-
Check carefully if there is any damage. If there is, immediately notify the Technical
Support Service of Cecotec.
Box contents:
-
Bamba ToothCare 1200 Jet Pro oral irrigator
-
7 nozzles
-
Instruction manual
3. OPERATION
UV disinfection
Use the disinfection UV light to clean the nozzles after every use. This system provides a
controlled disinfection.
44
BAMBA TOOTHCARE 1200 JET PRO
It has been checked that removes 99.9% of bacteria and viruses.
To activate the disinfection system, close the nozzle compartment door and turn the UV/ON/
OFF knob to the UV position.
The UV light will only turn on if the door is well closed. The light will turn off if the door is
open during the disinfection cycle. When closing it again, the cycle will start again.
The disinfection cycle acts for 15 minutes and then it turns off automatically.
Stop using the disinfection cycle if the UV light is on when the door is open or if the door is
broken. The UV light can be harmful to the human eye and skin.
Preparing the tank
Remove the tank from the base. Open the cover and fill the water tank with warm water.
Place the tank again in the base, press firmly and close the cover.
The tank cover can be completely removed to make its cleaning easy.
Inserting and removing nozzles Fig. 6
Insert the nozzle in the centre of the knob in the upper part of the handle and press until it
clicks. When it clicks you will see the knob lowers and stays fixed in this position. The color
ring will be almost touching the end of the knob if the nozzle is correctly blocked in place.
To remove the nozzle from the handle, press the nozzle release button and remove the
handle knob nozzle.
Pressure setting
Turn the pressure control knob to the lowest position for the first use. Increase pressure
gradually over time until the desired setting, or as directed by your dental professional.
Use mode
Select the nozzle you want to use and insert it as previously indicated.
Connect the plug to a power supply.
Lean over the sink and place the nozzle on your mouth. Slightly close your lips to avoid
splashes, but allow water to flow from your mouth to the sink.
Aim the nozzle at your teeth and with your free hand, turn the UV/OFF/ON switch to the ON
position.
Set the pressure with the pressure control knob and the jet direction by turning the knob on
the handle. Fig. 7
Direct the water jet in a 90º angle towards the gum.
To achieve better results, start in the molar area towards the front teeth. Fig. 8
Slide the nozzle over the gumline and stop between your teeth.
Keep the process until every area around and between teeth is clean.