Descargar Imprimir esta página

Emerio PAC-127068.1 Manual De Instrucciones página 11

Aire acondicionado portátil

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 109
E0 Code
E1 Code
E2 Code
E3 Code
Appliance stops
cooling after a
running cycle of 50
minutes.
TECHNICAL DATA
Notice: Operation temperature range:
Dry bulb temperature / Wet bulb temperature(℃)
Below data for your operating reference
Model
Rated voltage
Rated frequency
Rated input
Rated current
Cooling capacity
Moisture removal (L/H)
Air flow
ERP INFORMATION
Trademark
Model identification
Sound power (cooling)
Name of refrigerant
Rated power input for cooling (kW)
Rated energy efficiency ratio
GWP (kgCO
eq)
2
Energy efficiency class
Energy consumption for double ducts appliances (kWh/h)
Energy consumption for single duct appliances (kWh/h)
Power consumption in thermostat-off mode (W)
Power consumption in stand-by mode (W)
Cooling capacity
Room temperature sensor failed.
Condenser temperature sensor failed.
Water tray full when cooling.
Evaporator temperature sensor failed.
When the ambient room temperature
drops to 21⁰C or below for 50 minutes
during cooling mode, the appliance will
be stopped for 5 minutes by the default
programme.
PAC-127068.1
220-240V
50Hz
1345W
6.0A
3500W (12000Btu/h)
1.2
320m³/h
Replace the room temperature sensor.
Contact authorized service technician
for repair.
Replace condenser temperature sensor.
Contact authorized service technician
for repair.
Take off the rubber stopper and empty
the water.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
No action required. This is to avoid the
internal copper cooling pipes from
freezing. The appliance will resume
again after 5 minutes and this cycling
process will be repeated continuously.
Maximum cooling
35/24
Value
Emerio
PAC-127068.1
≦65dB(A)
R290 (0.215kg)
1.345
2.6
3
A
N.A
1.345
N.A
0.5W
3500W
- 10 -
Minimum cooling
18/12

Publicidad

loading