Quick Start Guide
It is highly recommended that you change th PIN to a 4 digit number that you will remember. If you have not entered
your PIN in the last 30 minutes, you will be asked to enter it before you can access the patient profiles.
If your PIN is entered incorrectly, you will be notified and the screen will refresh for you to re-enter your PIN.
If you have forgotten your PIN, please contact MGC Diagnostics or your local distributor to reset it.
Bedfont® Scientific Ltd.
Station Road, Harrietsham, Maidstone,
Kent, ME17 1JA England
Tel: +44 (0)1622 851122 Fax: +44 (0)1622
854860
Email: ask@bedfont.com
Web: www.bedfont.com
© Bedfont® Scientific Limited 2022
Issue 5 - March 2022, Part No: LAB767_MGC
Bedfont® Scientific Limited reserves the right to change or update his literature without prior notice.
Registered in: England and Wales. Registered No: 1289798
1. Press and hold the on / off button once to switch the monitor on and wait up
to 60 seconds for the monitor to stabilise .
2. Attach a new mouthpiece to the unit and select either the adult
breath test .
NOTE : To cancel the breath test, press the
3. As prompted onscreen by
NOTE : Do not inhale through the mouthpiece .
4. When the exhale icons appear,
blow gently into the mouthpiece . Make sure you are not covering the vent
holes .
NOTE : The exhalation time is approximately 12 seconds for an adult and 10
for a child.
5. The onscreen flow meter will guide you on the exhalation rate : continue
blowing until the green tick
NOTE : If you blow outside of the exhalation guidelines, the test will beep,
before signifying a fail, and a red cross
test or
6. Following the tick, a result will appear on the screen, in ppb .
7. You may save this result by pressing
home screen by pressing
8. If you choose to save your results you will be shown a list of patient profiles .
Select a previously set profile to add your result to, or select an empty profile
to set a new one . Set the profile by typing in a name or reference, and press
9. Remove and dispose of the mouthpiece in accordance with local waste and
disposal guidance .
10. If no further tests are required, press and hold the on / off button once to turn
the FeNObreath
Note: A PIN is required to save the reading to a patient profile, the default PIN is 0000
For a full copy of the manual please contact your local distributor
Taking a Breath Test
or
to view the result.
.
.
off and store on FeNObreath
TM
MGC Diagnostics Corporation
and its subsidiary Medisoft SA
350 Oak Grove Parkway, St. Paul, MN USA, 55127
Tel: +1 800 950 5597
1 Route de la Voie Cuivrée 5503 Sorinnes, Belgium
Tel: +32(0) 82 22 30 20
Web: www.mgcdiagnostics.com
icon.
, inhale until prompted to exhale .
or
, keep the monitor upright and
appears onscreen to signify a successful test .
will appear. Touch
. Alternatively, you can return to the
Dock to charge unit .
TM
Stephen Rowe
Cristimar E4-1
Ave Juan Carlos I
Los Cristianos, Arona, 38650
Santa Cruz de Tenerife,
Spain
or child
to retry the

Publicidad

loading

Resumen de contenidos para Bedfont FeNObreath

  • Página 1 Web: www.bedfont.com Web: www.mgcdiagnostics.com © Bedfont® Scientific Limited 2022 Issue 5 - March 2022, Part No: LAB767_MGC Bedfont® Scientific Limited reserves the right to change or update his literature without prior notice. Registered in: England and Wales. Registered No: 1289798...
  • Página 2 Web: www.bedfont.com Web: www.mgcdiagnostics.com © Bedfont® Scientific Limited 2022 Issue 5 - March 2022, Part No: LAB767_MGC Bedfont® Scientific Limited reserves the right to change or update his literature without prior notice. Registered in: England and Wales. Registered No: 1289798...