2. INSTALLATION
EN
2.1 Installation
Make sure that installation is performed correctly,
adhering to all directions in the specific installation
manual provided with the appliance.
Always connect the water before the
power.
2.2 Connection to the water system
The models provided with Ice Maker require a
connection to the domestic water supply system.
This can be executed through the 1/4" water line
(copper or polyethylene) to the house water supply.
The system pressure must be between 8 psi and 75
psi (between 0.5 bar and 5 bar).
Different pressures can cause malfunctions or
leaks in the water system.
The appliance should be supplied only
with drinkable water.
Make sure that installation is performed
correctly,
according
to
all
directions in the specific installation
manual provided with the appliance.
Do not attempt to use a locally sourced
garden hose threaded adapter or braided
supply line. It will strip the threads on
the appliance water connection solenoid.
8
2.3 Connection to the electrical power
supply
The appliance operates at 115 V AC, 60 Hz and is
equipped with a power supply cord with a 3-prong
grounded plug, which must be connected to a
corresponding 3-prong (15 Amp) grounding-type
wall receptacle.
Do not use extension cords and/or
multiple adapters for the power supply
connection.
of
the
3. BEFORE STARTING
3.1 Know your appliance
This manual will answer most of your questions
about the product's features. Should you require
further information, please check our website further
information, please:
>
call us 1-855-4FULGOR (1-855-438-5467)
>
visit fulgor-milano.com/us/en/assistance
Before calling, write down the model code
and serial number which are available on
the warranty certificate and on the rating
plate, and any messages which may have
appeared on the display.
The rating plate is located into the appliance, on side
cabinet, close to the shelves.
Before calling, please make sure to have the following
information ready:
Model code, serial number and proof of purchase
(date and dealer).
EN
9