Descargar Imprimir esta página

LaserLiner MultiScanner Plus Manual De Instrucciones página 17

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62
4
Calibration
Auto-Calibration
The automatic calibration is performed in METAL-SCAN
and AC-SCAN measurement immediately when the device
is switched on and when the measuring mode is switched.
Auto-Cal Plus
When an object has been found, the device performs another
automatic calibration in METAL-SCAN measurement. This
simplifies the process of isolating objects to be measured
and adjusting the device to different surfaces.
Manual calibration
Pressing the CAL button (d) manually calibrates
the device. This allows measurements to
be restarted and objects to be isolated more
precisely.
Maximum sensitivity is achieved when the
device is held in the air while calibrating. This can be useful for
METAL and AC-SCAN measurements.
The device and the wall must maintain contact during
!
calibration in STUD-SCAN mode and throughout the
entire measurement process. A hand should remain at
the device the entire time as well.
MultiScanner Plus
Metal,
wiring
or object
nearby.
Edge of
object
found.
Metal or
wiring
found.
Centre
of object
found.
17
EN

Publicidad

loading