FM10_DE_RU_80S_977091-02_final.qxp_Innenseiten_FM10.qxd 25.02.19 11:00 Seite 1
Observe the information given by the manufac-
GB
turer of the medium.
l
In practice, sprayed liquids are a mixture of
various substances whose composition is
only known to the manufacturer. The suit-
ability of the unit for a specific liquid must
N
therefore be determined before use by the
user in conjunction with the manufacturer
of the substance.
Foreseeable misuse
l
The device is not suitable for:
- formic and hydrofluoric acid in any
concentration.
- acids and alkalis at concentra tions
greater than the amounts quoted or
as mixtures.
- oils and fuels.
- Media which may cause or promote cracks
and fissures in the plastics used.
- liquids at temperatures over + 40°C.
- inflammable liquids.
- very tenacious or sticky liquids, or liquids
that leave residues, which cannot be
completely poured or flushed out of the
unit (oils and oil-bearing liquids).
l
On request, the manufacturer of the unit
can make available a detailed list of the
materials used in the parts of the unit for
more detailed examination.
l
Unauthorised changes to the unit made by
the user or inappropriate use shall render
null and void the liability of the manufac-
turer for any damage caused as a result.
Getting Started
WARNING!
Health risk through leaking cleaning
fluid!!
A leaking device or leaking components may
result in draining or spouting of cleaning fluid.
For this reason, observe the following safety
instructions:
- Check that the unit is in perfect condition
and properly sealed each time before use.
Pull up the safety / pressure relief valve (A)
by hand and check that it returns to the
starting position.
- Only operate or move device when standing
upright.
- Inspect all screw joints for tight fitting.
l
Unscrew the valve body (B) by rotating to
the left out of the container for filling.
l
Fill the tank, see "Max. filling volume" in
the Technical data section and the tank
scale for details on the maximum amount
that can be put in.
WARNING!
Contact with cleaning fluids poses a
health risk.
Observe the max. filling amount (see
Technical Data) and the correct dosing given
by the spray producer.
l
Screw valve body (B) back in and pump up
the device. Observe the safety / pressure
relief valve (A) during pumping. Peak pres-
sure is reached when the safety / pressure
relief valve is triggered. Any excess pres-
sure will escape through the safety / pres-
sure relief valve.
12