Speed settings for warm or cool weather depend
on factors such as the room size, ceiling height,
number of fans and so on.
NOTE: to operate the reverse function on this
fan, slide the reverse switch to the opposite
position. Do not operate reverse switch while fan
blades are in motion. Fan must be turned off and
blades stopped before reversing blade direction.
Warm weather - (Forward) A downward airflow
creates a cooling effect as shown in Fig. 19. This
allows you to set your air conditioner on a warmer
setting without affecting your comfort.
Cool weather - (Reverse) An upward airflow
moves warm air off the ceiling area as shown in
Fig. 20. This allows you to set your heating unit
on a cooler setting without affecting your
comfort.
9. Care of Your Fan
Figure 19
Figure 20
Reverse
Switch
Here are some suggestions to help you maintain
your fan.
1. Because of the fan's natural movement, some
connections may become loose. Check the
support connections, brackets, and blade
attachments twice a year. Make sure they are
secure. (It is not necessary to remove fan from
ceiling.)
2. Clean your fan periodically to help maintain its
new appearance over the years. Use only a soft
brush or lint-free cloth to avoid scratching the
finish. The plating is sealed with a lacquer to
minimize discoloration or tarnishing. Do not use
water when cleaning. This could damage the
motor, or the wood, or possibly cause an electrical
shock.
3. You can apply a light coat of furniture polish to
the wood blades for additional protection and
enhanced beauty. Cover small scratches with a
light application of shoe polish.
4. There is no need to oil your fan. The motor
has permanently lubricated bearings.
IMPORTANT
MAKE SURE THE POWER IS OFF AT THE
ELECTRICAL PANEL BOX BEFORE YOU
ATTEMPT ANY REPAIRS. REFER TO THE
SECTION "MAKING ELECTRICAL
CONNECTIONS"