Step 7. Carefully lift the assembly and rest the
hanger ball of downrod assembly on the hanger
bracket attached to the outlet box. Be sure the
groove in the hanger ball is lined up with the tab
on the hanger bracket. (Fig.10)
Tab
Groove
Figure 10
Make the Electric
Connections
WARNING: To avoid possible electrical shock,
be sure electricity is turned off at the main fuse
box before wiring.
5.
WARNING: Fan must be installed at a maximum
distance of 20 feet from the transmitting unit for
proper
signal
transmission
transmitting unit and the fan's receiving unit. If
you feel you do not have enough electrical wiring
knowledge or experience, have your fan installed
by a licensed electrician.
Step 1. Motor to receiver electrical connections:
Connect the black wire from the fan to the black
wire from the receiver. Connect the white wire
from the fan to the white wire from the receiver.
(Fig.11)
Step 2. Receiver to house supply wires electrical
connections: Connect the black (hot) wire from
the ceiling to the black wire marked "AC IN L"
from the receiver. Connect the white (neutral)
wire from the ceiling to the white wire marked
"AC IN N" from the receiver. (Fig.11)
Step 3. Ground wires connections: Connect the
GROUND wire from the house to the GREEN
wires from the motor assembly and mounting
plate. (Fig.11)
Secure all wire connections with the plastic wire
nuts provided.
Step 4. Place the receiver into the hanger bracket
and keep flat in opposition of ceiling. (Fig. 12)
Outlex box
between
the
White
Black
Black(AC IN L)
White (AC IN N)
Receiver
Black(TO MOTOR L)
Black
Figure 11
Hanger
bracket
Figure 12
Ground wire
Ground wire
White(TO MOTOR N)
White