Descargar Imprimir esta página

TDK-Lambda ZWX Serie Manual De Instrucciones página 18

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
Pin No.
CN41
1
2
Pin No.
(ZWX300 only)
1
CN51
2
3
4
*Output current of each connector pin must be less than 9A.
3.Terminal Connecting Method
Take care about the input wiring. Wrong connection cause the power supply spoil.
· Input must be off when making connections.
· Connect
terminal of input connector and mounting hole to protective earth of the equipment.
· The output load line and input line shall be separated to improve noise sensitivity.
· When connecting or removing connector, do not apply stress to PCB.
· Use the input/output connector specified in outline drawing. Also, use recommended crimping tool.
Connector is not included with this product.
INPUT/OUTPUT CONNECTOR (Common ZWX Series)
INPUT TERMINAL (CN1)
OUTPUT TERMINAL (CN21)
OUTPUT TERMINAL (CN31)
SIGNAL TERMINAL (CN41)
OUTPUT TERMINAL (CN51)
(ZWX300 only)
PWR_OK
PWR_OK signal terminal
PS_ON
PS_ON signal terminal
COM
GND terminal (All of COM are connected in this Power supply unit.)
COM
GND terminal (All of COM are connected in this Power supply unit.)
+12V-2
+12V output terminal (ZWX300 only)
+12V-2
+12V output terminal (ZWX300 only)
CONNECTOR
B3P5-VH(LF)(SN)
5566-10A-210
5557-10R-210
5566-22A-210
5557-22R-210
B2B-XH-AM(LF)(SN)
5566-04A-210
5557-04R-210
Function
Function
MACHING
TERMINAL PINS
HOUSING
VHR-5N
AWG18-22
AWG18-24
AWG18-24
XHP-2
AWG22
AWG18-24
-5-
TDK-Lambda
ZWX Series
Instruction Manual
MANUFACT
SVH-21T-P1.1
J.S.T.
BVH-21T-P1.1
5556PBT, 5556PBTL
MOLEX
5556PBT, 5556PBTL
MOLEX
BXH-001T-P0.6
J.S.T.
SXH-001T-P0.6
5556PBT, 5556PBTL
MOLEX

Publicidad

loading

Este manual también es adecuado para:

Zwx180Zwx240Zwx300