7
Troubleshooting
The determination of the causes of
existing defects and their elimination
always require increased attention
and caution. Pull out the mains plug
before hand!
A decrease in vacuuming capacity may result from a
number of different causes:
Container or filter bag 8 (Fig. 4 - page 3) must
be emptied, cleaned off or replaced.
Fold filter 5 (Fig. 2 - page 3) is heavily soiled. Clean
as described under section 5.2. After long use and
frequent cleaning, the permeability of the filter may
be reduced in a way that it must be replaced.
Motor protection filter 6 heavily soiled.
Connecting hose blocked.
8
Optional accessories
Transport case «MAX». Size IV
Filter bag set, 5 pieces (for 50 l container)
Filter bag set, 5 pieces (for 25 l container)
1 pair of fold filter cartridges (cellulose)
1 pair of fold filter cartridges (polyester)
4 m connecting hose, LW21 machine connection Ø
4 m connecting hose, LW27 machine connection Ø
5 m connecting hose, LW35 machine connection Ø
2.5 m connecting hose, LW49 machine connection Ø
4 m connecting hose, LW27 machine connection Ø
Hand extraction set
9
Exploded drawing and spare parts list
The corresponding information in respect of spare parts can be found on our homepage: www.mafell.com
If the decreased vacuuming capacity is not caused
by any of the reasons listed, do not make any further
attempts to pinpoint or repair it. Electrical safety can
be negatively affected if the device is tampered with
improperly.
Take the device to a MAFELL customer service
shop.
35 mm (1 3/8 in.) anti-static
35 mm (1 3/8 in.) anti-static
35 mm (1 3/8 in.) anti-static
58 (2 1/4 in.) mm static
35 (1 3/8 in.) mm static
-21-
Ref. No. 095 044
Ref. No. 093 677
Ref. No. 093 678
Ref.-No. 093 673
Ref.-No. 093 674
Ref. No. 093 679
Ref. No. 093 684
Ref. No. 093 681
Ref. No. 093 682
Ref. No. 093 680
Ref. No. 093 694