Sys-Ex Dump; Remote Function For Stroboscopes; Remote Function For Smoke Machines - EuroLite DMX OPERATOR Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Overview on the MIDI-functions:
Bank
Note-
number
00
01
02
03
Bank 1
04
05
06
07
08
09
Bank 2
10
...

6.7 Sys-Ex Dump

With this function, you can transmit the memory content between two DMX Scan Controls or to another Midi
Sys-Ex compatible Sequenzer or computer.
Please note: a received Sys-Ex Dump can delete all settings of a device. If you do not wish that a device
accidentally receives Sys-Ex data, switch it off or adjust another Midi-channel.
Connect the DMX-output of the sending device with the DMX-input of the receiving one.
Receive a Sys-Ex dump
Turn the device off.
Press and hold the Projector Select buttons 8 and 9 and Scene-button 2 and turn the unit on again.
The display shows "Receive" and the device is ready for receiving data.
When receiving the dump, all other functions are switched off. As soon as the transmission is complete or
cancelled due to errors, the controller returns to normal operation mode. If any error occurs during
transmission, the display shows "Error".
Send a Sys-Ex dump
Turn the device off.
Press and hold the Projector Select buttons 2 and 3 and Scene-button 1 and turn the unit on again.
The display shows "Transmit" and the device is ready for sending.
Press the Scene-buttons 7 and 8 at the same time in order to send the information.
When sending the dump, all other functions are switched off. As soon as the transmission is complete or
cancelled due to errors, the controller returns to normal operation mode. If any error occurs during
transmission, the display shows "Error".

6.8 Remote Function for Stroboscopes

By pressing and holding the stroboscope-contact-switch, you activate the stroboscope function. When you
release the contact switch, the stroboscope function stops.

6.9 Remote Function for Smoke Machines

By pressing and holding the smoke machine contact-switch, you activate the smoke function. When you
release the contact switch, the smoke function stops.
Function
Scene 1
Scene 2
Scene 3
Scene 4
Scene 5
Scene 6
Scene 7
Scene 8
Scene 1
Scene 2
Scene 3
...
Bank
Note-
number
Bank 15
112
Bank 15
113
Bank 15
114
Bank 15
115
Bank 15
116
Bank 15
117
Bank 15
118
Bank 15
119
Chase
120
Chase
121
Chase
122
Chase
123
Chase
124
Chase
125
Chase
126
21/41
Function
Scene 1
Scene 2
Scene 3
Scene 4
Scene 5
Scene 6
Scene 7
Scene 8
Chase 1
Chase 2
Chase 3
Chase 4
Chase 5
Chase 6
Blackout
70064520_V_2_0.DOC

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dmx scan control

Tabla de contenido