4.
Installation
Counterweight B) and cable entry must point in the same direction.
Installation
Over open tanks or sumps on a bracket. On closed tanks on the manhole cover with the float mounted
from the inside. In the absence of a manhole, i.e. the float can not be mounted from the inside, an
intermediate flange with an inside diameter of min. 125 mm of flange modules acc. to EN/DIN DN 125
or ANSI DN 5" should be used.
Mounting the vertical rod
Adjusting rings with grub screw (2 pieces) incl. tool and
cotter pin 2.5x16 are supplied in a separate bag.
1. Mount the vertical rod to the cross beam with
pivot pin C and secure with split pin S
2. Slide the adjusting ring A
and fix it in the required position.
3. Push the ball float onto the vertical rod.
4. Slide the adjusting ring A
and fix it in the required position.
5. Secure the adjusting rings and the ball float
against falling off with a cotter pin S
5.
Additional operating instructions
For electrical connection and initial start-up see appropriate operating instruction:
- for types A..., B...
- for types I..., IE9...
- for types XA...8, XB...8
- for types XI...8, XIE9...8
- for types I...8, IE9...8
- for types Z...8
- for types B...8
- for types B...5
- for types XA...5, XB...5
- for types XI...5, XIE9...5
- for types I...5, IE9...5
- for types Z...5
- for types Z...7
- for types B...7
- for types I...7, IE9...7
For pneumatic connection and initial start-up see appropriate operating instruction:
- for types P..., FP...
- for types M..., FM...
6.
Maintenance
Float modules must be periodically tested and cleaned, at least once annually. Procedures see
applicable switch operating instruction.
www.trimodbesta.com
.
1
onto the vertical rod
1
onto the vertical rod
2
.
2
see Operating instruction
see Operating instruction
(ATEX)
see Operating instruction
(ATEX)
see Operating instruction
(ATEX)
see Operating instruction
(ATEX)
see Operating instruction
(ATEX)
see Operating instruction
(IECEx)
see Operating instruction
(IECEx)
see Operating instruction
(IECEx)
see Operating instruction
(IECEx)
see Operating instruction
(IECEx)
see Operating instruction
(UKCA Ex)
see Operating instruction
(UKCA Ex)
see Operating instruction
(UKCA Ex)
see Operating instruction
see Operating instruction
see Operating instruction
8 │ 18
C
S
1
A
1
A
2
S
2
LTB002X
LTB008X
LTB001X
LTB004X
LTB006X
LTB007X
LTB010X
LTB011EN
LTB013EN
LTB014EN
LTB016EN
LTB017EN
LTB030EN
LTB031EN
LTB032EN
LTB003X
LTB005X
LTB020X │ 2023/01