Component Selection for Three-Phase Motor Starters
Contactors 100-C and Overload Relays 193-ED / 193-EE
230V
Current Range
50Hz
Min
Max
[kW]
[A]
[A]
9
35
10
9
38
11
9
44
13
To complete the cat. no., please replace
The electronic overload relay 193-EE* can be taken as well.
Component Selection for Single-Phase Motor Starters
Contactors 100-C and Single-Phase Overload Relays 193S-EE
230V
Current Range
50Hz
Min
Max
k [
W
]
[A]
[
] A
9
35
5.5
9
38
5.5
9
44
5
5 .
To complete the cat. no., please replace
Additional components
Neutral Terminal
Control Components required for Impulse Control
A
u
i x
a i l
y r
C
o
n
a t
t c
l B
c o
s k
f
r o
M
u
i t l
F -
u
n
t c
o i
n
P
s u
h
B
t u
o t
n
Base Mounted Contact Block 1 N.C.
Base Mounted Contact Block 1 N.O.
Reset Push Button Operator, Marking "R"
Control Components required for Maintained Control
Selector Switch Operator, non-illuminated, 2-position
Base Mounted Contact Block 1 N.O.
Reset Push Button Operator, Marking "R"
¥ For UL applications.
Schematic Diagram
3-phase
2-phase
L1
2
1
1- HAND
2- OFF
3- AUTO
96
97
95
98
1 WHEN E-STOP IS USED
ILLUMINATED HOA SELECTOR SWITCH
400V
500V
690V
50Hz
50Hz
50Hz
[kW]
[kW]
[kW]
15
15
11...15
18.5
18.5...20
18.5
20...22
22...25
22
with a coil voltage code.
1 1/2...2
with a coil voltage code.
D
e
c s
i r
t p
o i
n
S
d i
e
M
o
u
t n
n i
g
i w
h t
S
e
q
u
e
n
e c
T
r e
m
O
p
r e
t a
, r o
2
F
u
n
t c
o i
n
, s
M
a
k r
n i
s g
- I
2
1
Single-phase
L1
Wiring Tables
Impulse Control
2
2 WIRE
CONTROL
2
1
3
1
1
A1
A2
200V
230V
460V
575V
60Hz
60Hz
60Hz
60Hz
[HP]
[HP]
[HP]
[HP]
7 1/2
10
20
25
10
10
25
30
10
15
30
30
115V
200V
230V
60Hz
60Hz
60Hz
H [
] P
H [
] P
H [
] P
3
5
3
5
5
3
5
7 1/2
n i
l a
D
s e
g i
n
t a
o i
s n
O
2
Impulse Control
Multi Function Push Button
Add wires for common control. Remove if separate control is required.
L1 Control voltage supplied from external source.
From
To
Length [mm]
K1M - A2
( N )
280
K1M - 13
100
K1M - A1
S1 - 13
140
S1 - 31
100
S1 - 14
K1M - 14
140
F2 - 95
S1 - 32
140
(3)
100kA,
100kA,
690V
600V
DIN Fuses
Max. Fuse
Type gL/gG
Class CC, J
Contactor
63
50
100-C30
63
50
100-C37
80
70
100-C43
100kA,
100kA,
690V
600V
DIN Fuses
Max. Fuse
Type gL/gG
Class CC, J
Contactor
63
50
100-C30
63
50
100-C37
63
60
100-C43
R
e
q
i u
e r
d
Q
u
a
t n
y t i
¥
1
1
1
1
1
1
1
1
1
Maintained Control
O - I Selector Switch
Maintained Control
From
K1M - A2
K1M - A1
S1 - 14
SUPPLY CONDUCTOR
CAUTION:
BONDING BETWEEN METALLIC
CONDUITS MUST BE PROVIDED.
ATTENTION:
UNE LIAISON ÉLECTRIQUE
DOIT ÊTRE ASSURÉE ENTRE
GROUNDING ADAPTER KIT, CAT. NO. 198-GR1
LES CONDUITS MÉTALLIQUES
Components
Overload
Relay
00
193-ED1FD
00
193-ED1FD
00
193-ED1FD
Components
Overload
Relay
00
193S-EETD
00
193S-EETD
00
193S-EETD
Cat. No.
198E-PNT
100-SB10
800FP-U2EFFE
800F-BX01
800F-BX10
800FP-F611
800FP-SM22
800F-BX10
800FP-F611
To
Length [mm]
( N )
280
S1 - 13
140
F2 - 95
140
BONDING CONDUCTOR
SIZE (AWG)
QTY.
SIZE
14
1
14
12
1
12
10
2
12
FOR USE WITH ALLEN-BRADLEY
SEE APPLICABLE CODES AND LAW
FOR GROUNDING REQUIREMENTS