Technical Data
Code
Description
Blade
Voltage
Frequency
Current
Power
Speed
Maximum
cutting capacity
Duty cycle
Conductors
Insulation
WARNING
make it replaced by the manufacturer or in a
Power insulation in this tool is affected by liquid spills or splashing while operating.
Do not expose to rain, liquids and / or humidity.
WARNING
Power Requirements
WARNING
Tools with double insulation and reinforced are equipped with a
polarized plug (one prong is wider than the other). This plug will only fit in the right
way into a polarized outlet. If the plug cannot be introduced into the outlet, reverse
the plug. If it still doesn't fit, call a qualified electrician to install for you a polarized
outlet. Do not alter the plug in any way. Both insulation types eliminate the need of
both a grounded third power cord with three prongs or a grounded power
connection.
WARNING
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
11 000 RPM
90° 1 3/16'' (30 mm)
45° 1 7/8'' (22 mm)
16 AWG x 2C with insulating temperature of 221 °F
Class II
To prevent power discharge or serious accident if the power cable gets damaged
Before gaining access to terminals, all power circuits should be disconnected.
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
CAZ-EL-4-1/2N2
13978
Tile and masonry saw
4
/
"
1
2
127 V
60 Hz
10.4 A
1.7 Hp
Eje
Cutting
depth
50 minutes work per 20 minutes rest.
Maximum 6 hours daily.
IP Grade
Power cord grips used in this product: Y
Build quality: Reinforced insulation
Thermal insulation on motor winding: Class E
Authorized Service Center.
Extension gauge
from 5.9' to 49.2'
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
7/8" (22 mm)
Ceramic 1 3/16'' (30 mm)
Cement 3/4'' (19 mm)
Tile 1'' (25 mm)
IP20
|
higher than 49.2'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3