Descargar Imprimir esta página

Bosch Rexroth VM310 Manual Del Usuario página 12

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
12 /52
Bosch Rexroth AG
1 Technical Data
1
Technical Data
Designation
Order number
Input
Supply voltage
Supply current
Output
Output voltage intermediate circuit
Max. output voltage intermediate circuit
Nominal output
Maximum output
Supply voltage internal
VEE
VCC
VDD
Supply voltage external
24 V
ext
Interference suppression
Resistance to jamming
Admissible ambient temperature
Admissible relative humidity when in operation
Max. admissible altitude for use
For operation with altitudes of use greater than
1000 m above sea level
Admissible storage temperature
Admissible relative storage humidity
Protection class
System of protection
Dimensions (W x H x D)
Weight
Table 1:
Subject to alteration
VM310 | 3 609 929 A96/06.04
VM310
0 608 750 109
1 x 230 V or 3 x 230 V (± 10 %), 50 - 60 Hz
Depends on voltage and type of connection,
e. g. three-phase 230 V: 3 x 6,3 A
200 V
... 325 V
DC
DCNom
420 V
DC Max
2500 VA (at 230 V) three-phase
1250 VA (at 230 V) single-phase
10000 VA (at 230 V) for 5 s
24 V
4 A
(± 8 %)
5,1 V
7 A
(± 3 %)
–24 V
0,5 A
(+20 % / –10%)
24 V
6 A
(± 8 %)
EN 55011 class A
DIN EN 61000-4 part 2 up to part 5 intensity 4
0 up to 55 °C with ventilator
20 up to 90% non-condensing
2000 m above sea level (use of an isolating transfor-
mer is recommended when installed at altitudes gre-
ater than 2000 m above sea level)
Starting at 1000 m above sea level, a reduction in no-
minal output of approx. 1% per meter can occur due
to low air pressure.
–20 °C up to 70 °C
20 - 95 %
Protection class I
IP 20 (protection against accidental contact) when
installed
71 mm (14 DU) x 271 mm (6 HU) x 285 mm
3,0 kg
Nom
3 x 25 A
for 5 s
Peak
... 370 V
DC

Publicidad

loading