PACKAGE CONTENTS
Part
Description
Quantity
Fixture Body
A
B
Diffuser Shade
NOTE: Keep your receipt and these instructions for proof of purchase.
WARNING: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker before removing
an existing light fixture or installing the new one.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
INSTALLATION
Select a suitable location that can support the weight of the fixture. Determine the method for
mounting the fixture before drilling, based on the type of ceiling.
Turn the diffuser shade (B) counterclockwise to remove it from the fixture plate (A).
1
Screw the mounting screws (BB) directly to the electrical box.
2
• Connect the black wire labeled Driver + from the fixture plate (A) to the same color wire from
3
the electrical box.
•Connect the black wire labeled BBU + from the emergency driver to the same color wire from
the ON/OFF switch.
• Connect the green wire from the fixture plate (A) to the grounding wire from the electrical box.
• If 0-10v dimming circuit is available, connect the purple and pink wires from the power supply
box to the same color wires from the electrical box.
• If dimming is not desired, wrap the ends of the purple and pink wires with electrical tape to
cover the wire.
• Cover the wire connections using the wire connectors (AA).
• Wrap the wire connectors (AA) with electrical tape for a more secure connection.
• Position the wires back inside the electrical box.
• Align the keyholes in the fixture plate (A) with the mounting screws (BB), allowing the heads
4
of the screws (BB) to come through the large ends of the keyholes.
• Rotate the fixture plate (A) until the heads of the mounting screws (BB) slide into the narrow
ends of the keyholes.
• Tighten the mounting screws (BB) to secure the fixture plate (A) to the electrical box.
• Make the diffuser shade (B) notch face to emergency switch of the fixture plate (A).
5
• Turn the diffuser shade (B) clockwise to secure it to the fixture plate (A).
• Restore power at the electrical panel. Turn on the light switch to activate the fixture.
BATTERY BACK UP
The red button test switch allows you to test functionality of the BBU. When fixture is not connected to power, press and hold
the test button to check if the BBU is working. When fixture is connected to power, pressing the test button will flash once.
When fixture is connected to power the green indicator light will be on showing power is on and BBU is charging. If power is
disconnected (emergency power) from the fixture, the green indicator light will shut off and the fixture will be running on the
BBU. 90 min run time after at least 24 hour charge. Pressing the test button while on emergency power will turn off the BBU
and light will be off until power is restored.
ADJUSTING THE COLOR TEMPERATURE OF THE LIGHT
This LED light fixture allows you to customize the color temperature of the light using three settings: soft white, cool white, or daylight.
• Choose your favorite correlated color temperature (CCT) from three options: 3000k Soft White, 4000k Cool White, or 5000k Daylight.
• Move the toggle switch on the fixture plate (A) to make your selection before attaching the diffuser shade (B) to the fixture plate (A).
NOTICE: The factory setting for the correlated color temperature (CCT) is 3000K, which is the warmest white light.
CARE AND CLEANING
CAUTION: Before attempting to clean the tube and luminaire/light fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from the fuse box.
Clean with a soft, dry cloth. Do not use cleaners with chemicals, solvents, or harsh abrasives. Do not use liquid cleaner on the LEDs, LED driver, or wiring.
WARNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or other
injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker. • SUITABLE FOR
OPERATION IN AMBIENT NOT EXCEEDING 45°C. SUITABLE FOR DAMP LOCATIONS. MINIMUM 75°C SUPPLY CONDUCTORS. CAUTION-RISK OF SHOCK. DISCONNECT POWER BEFORE SERVICING.
NOTE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures: Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect
the equipment into an outlet on a circuit different from that to which the receiver is connected, and consult the dealer or an experienced radio/TV.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
USE AND CARE GUIDE
16" COLOR PREFERENCE
A
1
1
B
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com
Part # FM-16IN-1600LM-9-CP3-MV-LVD-EM
FLUSHMOUNT WITH BBU
®
HARDWARE INCLUDED
Part
Description
AA
Wire Connector
BB
Mounting Screw
Step 1:
A
B
Step 3:
BB
AA
Step 4:
BB
AA
A
Model # 54437611
Quantity
6
2
Step 2:
BB
Wall switch
AC-L
BBU+
AC-N
Driver+
0-10V+
Dimmer
0-10V-
Step 5:
A
B
A
3000K 4000K 5000K
AA
BB
Indicator light
Red button
C

Publicidad

loading

Resumen de contenidos para ETI FM-16IN-1600LM-9-CP3-MV-LVD-EM

  • Página 1 Model # 54437611 Part # FM-16IN-1600LM-9-CP3-MV-LVD-EM USE AND CARE GUIDE 16” COLOR PREFERENCE FLUSHMOUNT WITH BBU ® HARDWARE INCLUDED PACKAGE CONTENTS Part Description Quantity Part Description Quantity Wire Connector Fixture Body Mounting Screw Diffuser Shade NOTE: Keep your receipt and these instructions for proof of purchase.
  • Página 2 N° modèle 54437611 N° de pièce FM-16IN-1600LM-9-CP3-MV-LVD-EM GUIDE D’UTILISATION ET D’ENTRETIEN 16” COLOR PREFERENCE® ENCASTRÉ AVEC BBU MATÉRIEL INCLUS CONTENU DE L’EMBALLAGE Pièce Désignation Quantité Pièce Désignation Quantité Serre-fils Plateau de montage Vis de boîte électrique Diffuseur REMARQUE: Gardez votre facture ainsi que ces instructions comme preuves d’achat.
  • Página 3 Consulte el sitio web para obtener detalles sobre la garantía, la solución de problemas o el cuidado y la limpieza en www.ETiSSL.com. ¿Preguntas, problemas, piezas faltantes? Llame al Centro de Atención al Cliente de ETi en el horario de 8 a.m. - 5 p.m., HSC, de lunes a viernes.

Este manual también es adecuado para:

54437611