HOW TO INSTALL

CAUTION
When handling the unit, be careful to avoid cuts from the
sharp metal edges and aluminum fins on the front and
rear coils.
Tools Needed: Phillips Screw Driver, Drill (If pilot holes are
needed. (Tools not included).
Top Rail and Sliding Panels at each side are offset to provide
the proper pitch of 5/16" to the rear of the air conditioner.
1. Place unit on floor, a bench or a table. There is a Left
and Right Window Filler Panel - be sure to use the
proper panel for each side. When installed, the flange
for securing the panel in place to the window sill will
be facing into the room.
A. Hold the Accordion Panel
in one hand and gently
pull back the center to
free the open end. (Fig 2)
B. Slide the free end of the
panel into the cabinet.
Slide the panel down.
Be sure to leave enough
space to slip the top and
bottom of the frame into
the rails on the cabinet.
C. Once the panel has been
installed on the side of the cabinet, make sure it sits
securely inside the frame channel by making slight
adjustments. Slide the top and bottom ends of the
frame into the top and bottom rails of the cabinet.
D. Slide the panel all the way in and repeat on the
other side.
2. Keeping a firm grip on the air conditioner, carefully
place the unit into the window opening so the bottom
of the air conditioner frame is against the window
sill. Carefully close the window behind the top rail of
the unit. (it is suggested to keep a downward angle
so accumulated rain water can drain out from the
backside of the unit).
3. Extend the side panels out against the window frame.
4. Place the frame lock between the frame extensions
and the window sill. Drive 3/4" (19mm) locking screws
through the frame lock an into the sill. Note: To
prevent window sill from splitting, drill 1/8" (3mm) pilot
holes before driving screws.
5. Drive 1/2" (12.7mm) locking screws through frame
holes into window sash.
6. To secure lower sash in place, attach right angle sash
lock with 3/4" (19mm) screw.
7. Cut foam seal and insert in the space between the
upper and lower sashes.
If AC is Blocked by Storm Window
Add wood as shown in Fig. 3, or remove storm window
before air conditioner is installed.
If storm window frame must remain, be sure the drain holes
or slots are not caulked or painted shut. Accumulated
rain water or condensation must be allowed to drain out.
Electronic Window
Air Conditioner
Fig. 3
Storm window
frame or other
obstruction.
Removing AC From Window
• Turn AC off and disconnect power cord.
• Remove sash seal from between windows and unscrew
safety lock.
• Remove screws installed through frame and frame lock.
• Close (slide) side panels into frame.
• Keeping a firm grip on air conditioner, raise sash and
carefully "rock" air conditioner backward to drain any
Fig. 2
condensate water in base of unit. Be careful not to spill
any remaining water while lifting unit from window. Store
parts WITH air conditioner.

AIR CONDITIONER USE

Operating your air conditioner properly helps you to obtain
the best possible results. This section explains proper air
conditioner operation.
IMPORTANT:
• If you turn off the air conditioner, wait at least 3 minutes
before turning it back on. This prevents the air conditioner
from blowing a fuse or tripping a circuit breaker.
• Do not try to operate your air conditioner in the cooling
mode when outside temperature is below 65°F (18°C).
The inside evaporator coil will freeze up, and the air
conditioner will not operate properly.
Note: In the event of a power failure, your air conditioner
will operate at the previous settings when the power
is restored.