3
When manufacturer's instructions specify
the distance from the edge of the door to the
center of the hinge-cup hole, see the table
directional for the correct Edge Indexer setting.
ATTENTION
If installation instructions supplied
with your hinges are vague, incomplete, or
nonexistent, please contact the manufacturer
or hardware supplier for complete installation
information. Major hardware manufacturers have
this information on their Web sites.
Position the Base with the Edge Indexer
cams on the bottom of the Base against the
hinge edge of the door. Set the distance from
the top or bottom edge of the door by using
the scale on the beveled edge of the Base
(3½" mark aligned with edge shown) or by
aligning a marked centerline with "0" on the
scale. Clamp the Base to the door with two
clamps, one above and one below the Drill
Guide socket.
ATTENTION
To keep both Edge Indexer cams in
contact with the door, the distance from the top or
bottom end of the door to the center of the hinge-
cup hole must be at least 2" [51mm].
Assembly
Distance from door
edge to hole center
Using the Jig
21mm
22mm
23mm
24mm
Hinge
centerline
mark
Edge Indexer
setting
3mm
4mm
5mm
6mm
Centerline notches
Mark on scale
aligned with edge