4) Make sure that the correct welding wire is installed in the machine.
5) Connect the shielding gas cylinder with a pressure reducer to the gas inlet on the rear panel
of the machine using a gas hose.
6) Plug the power cord into an electrical outlet and start the machine. After connecting the
mass cable to the workpiece, work can begin.
Welding with the FCAW method ("MIG/MAG" without gas)
1) Insert the welding gun cable plug into the Euro MIG/MAG output socket on the front panel of
the machine and tighten it.
2) Insert the ground wire plug into the terminal marked "+" on the welding machine's front
panel and tighten it clockwise.
3) Insert the polarity reversal plug into the terminal marked with the "-" symbol on the panel
inside the welding machine (where the welding wire is to be installed) and tighten it
clockwise: