Press Calibration/Fluid Type Factor (CAL)
The TT10 Series Meters provide 20 preset factors for different fluid types/viscosities.
Use of calibration factors is intended to provide the most accurate metering solution for a specific fluid. A CAL factor of 0 is for use with the thinnest
fluids and increases for higher viscosity fluids.
3
1.
Press and hold button
for three seconds. The current dispensed count value will disappear and only the CAL icon and the current value
will be displayed.
2.
Repeatedly pushing button
3.
After the desired fluid factor has been selected, press button
Fluid
cSt
Heptane
0.36
0.48
Gasoline
0.63
0.84
Water/DEF
1.12
1.48
Mineral Spirits
1.98
NOTE: Use of the CAL/Fluid factor is independent from performing a calibration against a known volume. The meter is calibrated at the factory,
but performing a field calibration may further improve meter accuracy.
Fluid Calibration
Fluid calibration requires a container of a known volume at least 5 gallons or larger that is compatible with the fluid being metered. A larger volume
may be used and may improve calibration accuracy, but do not exceed 99.99 units of measure.
NOTE: Before performing a fluid calibration, ensure you have selected the closest matching CAL/fluid factor to ensure the best meter accuracy.
2
4
1.
Press the
and
buttons at the same time and hold for three seconds. Display will show the firmware version.
3
2.
Press button
to enter calibration mode. Unit of measure will be displayed.
3
3.
Press button
. The display will show "FILL".
4.
Dispense fluid into container. "FILL" will blink on the display when flow is detected.
5.
After dispensing fluid, press the
4
6.
Press button
to increment digit to the amount of fluid dispensed (e.g."05.00"). Press the
start back at left-most digit if needed.
7.
After number is loaded, press the
Display now shows the configured CAL factor.
8.
9.
Press the
button again and the firmware version will be displayed.
2
10. Press the
button again to return to normal operating mode.
NOTE: If value entered is out of an acceptable range, display will read "Err0" and meter will revert to previous settings. See Table 2 on page 8 for the
Troubleshooting Guide.
If you are metering in ounces, pints, or quarts, it may be easier to switch the meter to a larger unit of measure such as gallons or liters for the
calibration process and then change back to the desired unit of measure.
fillrite.com
TT10 IN-LINE TURBINE METER
3
will increment the number up to 19, then return back to zero.
Table 1: CAL Factor Table for Fluids at 70ºF / 21ºC
Cal
Fluid
0
Kerosene
1
Diesel
2
B100
3
4
Jet Fuel
5
6
button. Left digit of the display will blink ("00.00").
button again to accept entered volume.
2
to lock in the fluid factor and return the meter to normal operating mode.
cSt
Cal
Fluid
2.62
7
Ethylene Glycol
3.48
8
2,4-D
4.62
9
Glyphosphate
6.15
10
Atrazine 4L
11
8.16
Propylene Glycol
10.8
12
10W-30 Oil/ATF
14.4
13
INSTALLATION AND OPERATION MANUAL
cSt
19.1
25.4
33.7
44.8
59.5
79.0
button to move to right. Press button
Cal
14
15
16
17
18
19
2
to
6