Descargar Imprimir esta página

Emos P5630S Manual De Instrucciones página 15

Ocultar thumbs Ver también para P5630S:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 283
• The time can be set in the EMOS GoSmart app in the Boost tab.
• The length of the heating interval can be set to 100–900 seconds.
Temperature Differential Setting
• This feature can only be adjusted on the screen of the thermostatic head itself.
• The differential can be set to 0.5 °C, 1 °C, 1.5 °C.
• The temperature differential (hysteresis) is the difference in temperature
required for switching the heating system on and off.
• For instance, if you set the temperature to 20 °C and the differential to
1 °C, the thermostatic head activates heating as soon as room temperature
drops to 19 °C and switches heating off when temperature reaches 21 °C.
Controlling the Valve
• Can only be adjusted on the screen of the thermostatic head itself.
• These controls enable you to set how the valve of the thermostatic head
is to be controlled.
• Value = 0: control in accordance with the modes you have set; value = 1
automatic control based on current temperature.
• When automatic control is selected, the valve is controlled as follows:
• If the temperature you set is 2 °C higher than the temperature in the
room, the valve is 100 % open.
• If the temperature you set is 1 °C higher than the temperature in the
room, the valve is 75 % open.
• If the temperature you set is the same (±0.5 °C) as the temperature in
the room, the valve is 50 % open.
• If the temperature you set is 1 °C lower than the temperature in the
room, the valve is 25 % open.
• If the temperature you set is 2 °C lower than the temperature in the
room, the valve is closed.
Setting Modes and Functions on the Screen of the Thermostatic Head
• Once batteries are inserted, the thermostatic head turns on and the entire
screen lights up. Then the
button allows you to set the current time. Set, in this order, hours, minutes
icon will light up. Pressing the
15

Publicidad

loading