Install the pipe socket with hose on the pipe for predilut-
ed detergent. The recommended pipe size is 3/4" (The
minimum is 1/2" pipe). The connection prediluted inlet of
the unit is internal 1/2" thread.
Installation of hoses for prediluted detergents in satel-
lite
Make sure the hose is cut at an 90°angle, and the
union nut is on the hose.
The hose has to be pressed up to the thread.
Keep the pressure untill the union nut is mounted by
hand.
Use spanners to secure the union nut. Make sure
the hose is secured before opening the prediluted
detergent supply.
6.8. Hose Connection
• The special hose fitted with spray gun/outlet valve
is connected to the outlet quick coupling of the unit
(layout drawing).
• Maximum hose length: 30 m.
• It is recommended only to use Nilfisk Food hoses,
which have been tested for resistance.
6.9. Mounting of hose for pre-diluted chemical
1. First - connect the inlet nozzle to the inlet pipe
2. Second - connect the inlet nozzle to the inlet
hose
110006227
15