WARNING! Do not open or disassemble the device. Attempting to service the unit
yourself may cause the risk of electrical shock or fire. Please follow the safety
instructions when working on the device.
In a few cases , the charging process will finish very quickly, but the battery is not fully charged or
does not deliver the desired voltage or power. The reason for this case could be that the battery is
broken and needs to be replaced. If the device doesn't work at all, an internal fuse might be blown.
This happens always for a reason. Do not try to replace internal fuses yourself. The device has to
be checked by the manufacturer or by an authorized service.
ERROR DIAGNOSTICS
Error conditions are indicated in the
Error
Solid Red LED
Flashing Yellow
LED
Solid Yellow LED
Flashing Red LED
10
TROUBLESHOOTING
LED display.
Standard Charging Mode
Recovery Mode
Battery capacity may be too high for the selected mode. Verify the battery
capacity and charge mode. If battery capacity is in range, change charge
Battery voltage is too high or too low for the selected mode. Verify the
battery voltage and charge mode.
Reverse polarity. Reverse the battery connections.
Reason/Solution
The battery is not accepting a charge.
Change charge mode to Recovery Mode.
The battery cannot be recovered.
mode to Recovery Mode.