Control panel with built-in receiver for axis centre motors and operators for roller doors and shutters. It enables the memorizing of 27
transmitters (expandable to 500).
TECHNICAL DATA
Receiver data
Frequency
Adjustable activation distance
Coding
Memory
Number of channels
Control panel data
Power supply
Maximum motor power
Standby/Op. consumption
Motor fuse
Op. temperature
Watertightness
Box dimensions
STOP, OPEN and CLOSE inputs (only ROLL868 DMR-P version)
INSTALLATION
Fit the rear of the box to the wall using the raw plugs and screws supplied. Pass the cables through the bottom of the equipment.
Proceed with the starting up of the equipment.
STARTING UP
1. Connect the motor and the power supply.
Connect the motor as shown in the figure above: U (open), V (close), W (common).
Connect the equipment to the 230Vac power supply as shown in the figure above. The red pilot light is activated every 5
seconds indicating the correct power supply to the equipment.
2. Set the switch selector to the desired operating option.
Selector
Position ON (default option)
1
Dead man operating: the control panel operates in
dead man mode for open and close, provided it
is operated from inside the coverage area, previously
adjusted.
3. Programming the dead man transmitters.
Press the programming button PROG for 1 sec: the programming pilot light will come on and the equipment will emit an
acoustic signal. Press any channel of the transmitter, and wait to hear a 0,5 seconds acoustic signal.
Configuration of the transmitter programming into the receiver
Pressing any channel of the transmitter, the relays will be activated by: 1rst channel Open and 2nd channel Close, and
3rd channel Open, 4th channel Close
Note: This control panel only works with dead man transmitters.
ROLL868 DMR / ROLL868 DMR-P
868,35MHz
0 – 20 m
High safety changing code
27 codes (expandable to 500 codes)
2 (open and close)
230V AC ± 10%
750W (@100.000 manoeuvres) – 1200W
<1mA / max. 5 mA.
6A
-20ºC to +85ºC
IP54 (with IP65 packing seal)
140x220x55mm
OPEN and CLOSE: Perform the same function as the transmitter
channels.
STOP: Stop the manoeuver. If not used, make a bridge on the terminals.
Position OFF
Semi-automatic operating: The control panel operates in
semi-automatic mode for open (maximum manoeuvre 2
minutes),
without
transmitter and receiver, and in dead man mode for close
(provided it is operated from inside the coverage area).
restriction
on distance between
Led R1
ON
EN