FEATURES
• Access control for a single door with a single code;
• Personal access code for "Programming Menu" (from 4 to 8 digits);
• Programming of the working time of relay from 1 up to 99
seconds or permanent ("remain open time");
• Possibility to activate the relay by shorting terminals SW
and –. Relay will operate for the programmed time;
• Electronic call tone by pressing directly Clear/Bell button (re-
quires Art. 512A connected on terminals CA and
• Audio and visual warnings during the keypad operation. Each
time a button is pressed, the keypad emits an acoustic signal
(buzzer). Two LEDs provide warnings for the following operation:
» Green LED on for 2 seconds = correct code entered;
» Red LED always on = programming mode active.
• Self protection against unauthorized access attempts. In case
is entered a wrong code, the keypad emits a continuos melo-
dy (4 seconds approx) then, continuing the insertion of wrong
codes, the duration of the error signal is increased each time
so that each access attempt requires more time.
• Dry contacts Relay. Are available the terminals C, NC and NO
with 24Vac/dc@5A;
• Power requirements for Art. VX810N: 12V/24Vac/dc,100mA Max.
INITIALIZATION
When the installation is concluded and carried out according
to the wiring diagram, power up the system and program it by
programming flow chart.
RETURN SYSTEM TO PRESET ENGINEER'S FACTORY CODE
• Turn off power to code lock;
• Keep ENTER button pressed while turning the power back on;
• Release ENTER button;
• The engineer's code is now set to 11111111 (eight times one).
Art. VX810N - Installation instructions
Codelock
);
PROGRAMMING FLOW CHART
Press "ENTER"
Confirm the "Engineer's
code" or enter a new one
Press "ENTER"
Press "ENTER"
Press "ENTER"
System ready to use
OPERATION
• Enter the "Relay code" (door opening code) then press the
ENTER button:
» If the code is correct, the relay switches on for the pro-
grammed time and the LED will illuminate for 2 seconds
approx;
» If the code is wrong, the buzzer emits a melody having a
duration of 4 seconds approx. Each wrong code insertion
increases the duration (self- protection);
• To enable the sounder Art. 512A, press the button Clear/Bell
before press any other button: the sounder will ring 3 times.
If for the relay is set the mode "Remain open time", to switch the
relay once switched the first time, enter the relay code again the
press the Clear button.
- 1 -
Power up with
12/24Vac/dc
Enter preset
8 x 1 (11111111)
"Engineer's code"
Red LED will be ON
4 to 8 digits
Melody
Enter
4 to 8 digits
"relay code"
Melody
2 digits (01-99) seconds
Enter
I.E. 05 = 5 seconds
"relay time"
00 = remain open time
Red LED will be OFF
66800058 - V4.0 - 31/01/21

Publicidad

loading

Resumen de contenidos para Videx VX810N

  • Página 1 • Dry contacts Relay. Are available the terminals C, NC and NO Press “ENTER” Red LED will be OFF with 24Vac/dc@5A; • Power requirements for Art. VX810N: 12V/24Vac/dc,100mA Max. System ready to use INITIALIZATION OPERATION When the installation is concluded and carried out according •...
  • Página 2 Se per il relé è attivo il modo “commutazione di stato” (tempo volte uno). relé = 00), per disattivare il relé una volta attivato, digitare nuo- vamente il codice quindi premere il pulsante CLEAR. - 2 - Art. VX810N - Istruzioni di installazione 66800058 - V4.0 - 31/01/21...
  • Página 3 12Vac 12/24Vac/dc Title: Data creazione: Foglio 17/03/2016 Titolo: Data modifica: 17/03/2016 Videx Electronics S.p.A. Notes: Autore: Marco Rongoni Via del Lavoro 1, 63846 Monte Giberto (AP) Note: Cod.File: Phone: +39 0734 631669 - Fax +39 0734 631669 99975125na.dwg www.videx.it - info@videx.it - 3 - 66800058 - V4.0 - 31/01/21...
  • Página 4 DISPOSAL In accordance with the Legislative Decree no. 49 of 14 March 2014 “Implementation of the Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The crossed-out bin symbol on the equipment or on the packaging indicates that when the product reaches the end of its lifetime, it must be collected separately from mixed municipal waste.
  • Página 5 - 5 - 66800058 - V4.0 - 31/01/21...
  • Página 6 - 6 - 66800058 - V4.0 - 31/01/21...
  • Página 7 - 7 - 66800058 - V4.0 - 31/01/21...
  • Página 8 MANUFACTURER VIDEX ELECTRONICS S.P.A. FABBRICANTE Via del Lavoro, 1 FABRICANT 63846 Monte Giberto (FM) Italy FABRICANTE Tel (+39) 0734 631669 FABRIKANT Fax (+39) 0734 632475 www.videx.it - info@videx.it FABRICANTE ‫ال� ش كة المص ن ِّ عة‬ CUSTOMER SUPPORT VIDEX ELECTRONICS S.P.A.